The command can be found in the Pipeline Workshop under Model Building as so

Get_Vicon_Model_Metric
! /CALIBRATION_FILE=
! /MP_FILE_NAME=
! /METRIC_NAMES=
! /DEFAULT_METRIC_VALUES=
! /NAME_PREFIX=V_
;

Command Parameters

The following table shows the command parameters seen above and their descriptions:

CALIBRATION_FILE The Link Model in which the metrics will be stored if empty or =*, the current link model is used
MP_FILE_NAME The Vicon MP file ensure it is full pathname, if empty, the user is prompted for the filename
METRIC_NAMES The names of the metric, if empty or =*, all names in the .mp file are selected
DEFAULT_METRIC_VALUES Default name value
NAME_PREFIX Prefix for the given name

Example

Given an MP file containing the following information:

$RKnee_Width = 150.0
$RFoot_Width = 100.0
$LKnee_Width = 150.0
$LFoot_Width = 100.0

and the command

Get_Vicon_Model_Metric
/CALIBRATION_FILE=*
/MP_FILE_NAME=
/METRIC_NAMES=
/METRIC_VALUES=
/NAME_PREFIX=
;
  • The current active model will be used.
  • The user will be prompted for the MP file name.
  • All 4 metric values in the MP file will be added to the model subject metrics
  • No prefix will be added to the names.
Get_Vicon_Model_Metric
/CALIBRATION_FILE=
/MP_FILE_NAME=
/METRIC_NAMES=RHip_Radius
/DEFAULT_METRIC_VALUES=0.5*DISTANCE(RIGHT_HIP,LEFT_HIP)
/NAME_PREFIX=
;
  • RHip_Radius is not part of the MP file
  • A default metric value has been provided
  • A model metric RHip_Radius will be created (or modified)
  • The value of the metric will be the expression 0.5*DISTANCE(RIGHT_HIP,LEFT_HIP)