This is an old revision of the document!
Table of Contents
Metric Minimum
Overview
The Metric Minimum command computes the Minimum Value of a Signal and stores the value as a metric. It can be found within the Pipeline Workshop under Metric.
Pipeline Command
The syntax for the function is as follows:
Metric_Minimum ! /RESULT_METRIC_FOLDER=PROCESSED /RESULT_METRIC_NAME= ! /APPLY_AS_SUFFIX_TO_SIGNAL_NAME=FALSE /SIGNAL_TYPES= ! /SIGNAL_FOLDER=ORIGINAL ! /SIGNAL_NAMES= ! /COMPONENT_SEQUENCE= /EVENT_SEQUENCE= /EXCLUDE_EVENTS= ! /GENERATE_MEAN_AND_STDDEV=TRUE ! /GENERATE_MEAN_AND_STDDEV_ACROSS_SUBJECTS=FALSE ! /APPEND_TO_EXISTING_VALUES=FALSE ! /CREATE_GLOBAL_MINIMUM=FALSE ! /CREATE_TRIAL_MINIMUM=FALSE ;
Command Parameters
The Parameters for the function is as follows:
Metric_Minimum | |
/RESULT_METRIC_NAME= | The name of the metric signal created |
!/APPLY_AS_SUFFIX_TO_SIGNAL_NAME=FALSE | Add a suffix to the signal name |
!/RESULT_METRIC_FOLDER=PROCESSED | Name of results folder |
/SIGNAL_TYPES=TARGET | |
/SIGNAL_NAMES= | Signal |
/SIGNAL_FOLDER=ORIGINAL | |
/COMPONENT_SEQUENCE | Which component of the signal will be used for statistical analysis of the sequence. |
/EVENT_SEQUENCE= | Specify the sequence of Events. Any number of Events can be entered (separated by +). |
This specific sequence of events must be true for a metric to be computed. | |
The metric is computed from the first event in the sequence to the last event in the sequence | |
/EXCLUDE_EVENTS= | If this event occurs between the first and last event, do not computed a metric |
! /Generate_Mean_and_Stddev=TRUE | Generate the mean and standard deviation of this metric across ranges and files |
/Generate_Mean_and_Stddev_Across_Subjects | Generate the mean and standard deviation of this metric across all subjects |
! /APPEND_TO_EXISTING_VALUES=FALSE | Metrics can replace an existing signal or be appended to it. |
! /CREATE_GLOBAL_MINIMUM=FALSE | Create minimum value across all trials |
! /CREATE_TRIAL_MINIMUM=FALSE | Create minimum value for this trial |
Dialog
The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the Edit button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below.
The dialog box allows you to assign values to the command parameters outlined above.
Example
In the following example, compute the Minimum Value of the derived signal HANDSPEED between the events FRAME1 and GO, with any range containing the Event SPEED_CHANGE being ignored.
Metric_Minimum /RESULT_METRIC_NAME=_MEAN /APPLY_AS_SUFFIX_TO_SIGNAL_NAME=TRUE /RESULT_METRIC_FOLDER=PROCESSED /SIGNAL_TYPES=DERIVED /SIGNAL_NAMES=HANDSPEED /SIGNAL_FOLDER=PROCESSED /SIGNAL_COMPONENTS=ALL_COMPONENTS /EVENT_SEQUENCE=FRAME1 + GO /EXCLUDE_EVENTS=SPEED_CHANGE /GENERATE_MEAN_AND_STDDEV=TRUE /APPEND_TO_EXISTING_VALUES=FALSE ! /CREATE_GLOBAL_MAXIMUM=FALSE ;