File Commands Overview

Visual3D's file commands allows users to automate how files are loaded and managed within the workspace. They are separated into three categories: file management, file open/import, and file save/export.

File_Management

Command Description
Exit_Workspace Exits Visual3D. This is useful when an external program launches Visual3D with a pipeline. When the pipeline is finished executing, Visual3D is closed.
Recalc Recalculate the link model, event dependencies, and execute the RECALC Pipeline.
Clear_Recalc_Pipeline Clears the current RECALC Pipeline.
Select_Active_File Many of the pipeline commands in Visual3D act on the active files only, and only active file is animated in the 3D viewer.
Files_Close Closes the active file.
File_New Clears the Workspace. Removes all models, motion trials, and the Global Workspace.
File_Rename Renames the file.
Assign_Tags_to_File Files can be associated with other files opened in the Visual3D workspace by assigning a TAG to the file.
Combine_Tags Use boolean logic to combine TAGS into a new TAG.
Remove_Tags Removes the specified files from the TAG. Select ALL_FILES, a TAG, or a movement trial.
Remove_CMO_History Deletes the workspace's revision history.
Load_CMO_Library Loads a CMO Library, which are used to handle large data sets. Common use cases include creating a normal database for comparisons or processing data across multiple subjects.
Unload_CMO_Library Unloads the CMO Library.
Copy_Point_Descriptions_To_Analog_Labels
Copy_Point_Descriptions_To_Point_Labels Motion Analysis Corporation exports C3D files that are consistent with an early version of the C3D file format. One of the restrictions in the early format was that POINT LABELS (e.g. names of the markers) were allowed to have only 4 characters. This command will cause Visual3D to copy the marker DESCRIPTION PARAMETER into the marker LABEL PARAMETER thus giving markers their long names.
Create_Targets_For_LinkModelBased_Rotations
Create_Targets_For_LinkModelBased_Rotations_From_Velocity
Joint_Rotations_From_PSU_IMU
Fix_MAC_Eva7_C3DFile

Visual3D does not act as a general C3D editor. Several commands, however, exist to edit specific parameters in the C3D file:

Command Description
Modify_Analog_Parameters This command can be used to change a selection of the ANALOG parameters in a C3D file. There must be the same number of values in the LABELS, SCALE, and OFFSET entries. The command will modify the parameters in order.
Modify_C3D_Manufacturer
Modify_Point_Parameters The command Modify_Point_Parameters will modify the POINT LABELS (e.g. Marker Names) in the C3D file. The LABELS listed will be applied to the POINT parameters in the order listed in the C3D file. If fewer LABELS are specified in the command than exist in the C3D file, then only the number of LABELS specified will be modified.
Modify_C3D_Subjects_Parameters Modify the SUBJECT parameter group
Modify_Point_Rate Modify the point and/or analog rate in the c3d file
Remove_Prefix_From_Point_Labels Vicon Corporation's Workstation software provides an option to add a prefix to all of the marker labels. This causes Visual3D a big problem because Visual3D assumes that markers are named consistently between files, especially between the standing trial and the movement trials.
Upsample_Point_Data_To_Analog_Rate
Downsample_Data
Modify_C3D_Trial_Parameters Modify the TRIAL parameter group.

File_Open/Import

Command Description
File_Open Adds a file to the Visual3D Workspace.
Import_Data_From_ASCII_File Imports signals from an ASCII file formatted using the Visual3D_ASCII_Format.
Import_Analog_Signals
Import_Analog_ANB_Signals
Import_Analog_Bioware_Signals
Import_Analog_Frappier_Signals
Import_Analog_Fsv_Signals
Import_Analog_NDI_Signals Imports Analog signals from NDI Toolbench into a C3D file.
Import_Analog_Noraxon_EMG_Signals
Import_Pedar_Data
Import_Analog_SON_Signals
Import_Analog_Signals_From_AMTI_Ascii_File The ASCII file exported by AMTI is a very simple file with no header, and the data stored in columns.
Import_Analog_Signals_From_Arsalis_Ascii_File
Import_Analog_Signals_From_DASYLAB_Ascii_File
Import_Analog_Signals_From_Delsys_Ascii_File
Import_Analog_Signals_From_Microstrain_Ascii_File
Import_Analog_Signals_From_Winternet_Signals
Import_Analog_Signals_From_ADInstruments_Chart_Ascii_File
Import_Data_From_ASCII_File
Import_Analog_Signals_From_DATAPAC_Files
Import_Signals_From_C3D_File This command imports signals from a C3D file into the Active File.
Import_Surrey_Force_Platform_Signals
Merge_Aurora_Files
Import_FSV_Files The FSV/TSV file formats were originally developed by Manfred Berger from Innovision Systems and are currently used by Qualisys and Innovision.
Import_Analog_Signals_From_Fsv_File Importing ANALOG signals stored in an fsv file into an existing c3d file.

File_Save/Export

Command Description
File_Save Save the current workspace to the active CMZ file.
File_Save_As Save the current workspace to a new CMZ file.
Export_3D_Animation_To_Image Exporting a snapshot of the animation viewer to a file on disk.
Export_3D_Animation_To_Video
Export_C3DFile Export one or more C3D files from the Workspace.
Export_Data_To_ASCII_File
Export_Polygon_C3DFile Export a file from the Workspace to a C3D file suitable for Vicon's Polygon program.
Export_To_RDBMS

See Also

For more pipeline commands, please see the Pipeline Commands Reference page.