-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in The Checklist Manifesto 
  
-There are many crucial steps in collecting "routine" motion capture data. 
- 
-The following checklist is a starting point from which Motion Capture Laboratories can build their own. 
- 
-We encourage users to contribute to this list by sending additional tasks to support@c-motion.com 
- 
-====Before Patient's Arrival==== 
-  * Turn on ALL systems 
-  * Item Verify Position and Orientation 
-    * Verify the position and orientation of Motion Capture Cameras 
-    * Verify the position and orientation of Force Platforms 
-    * Verify the position and orientation of Force Structures 
-    * Verify the position and orientation of Obstacles or Environment objects 
-  * Perform System Calibration  
-    * Perform static and/or dynamic calibrations of data collection devices 
-    * Verify results against the Standards developed/referenced by your laboratory 
-  * Verify the protocol being used for the session 
-    * Verify the experimental protocol for the current data collection session 
-  * Set appropriate system settings 
-    * As per experimental protocol, set and verify system settings 
-      * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc. 
-  * Zero Force Plates and Perform CalTester test 
-    * Perform Caltester test at a minimum of 2 locations on each force platform 
-    * Verify against prior laboratory results 
-  * Prepare necessary markers and supplies 
- 
-====Patient's Arrival==== 
-  * Obtain informed consent 
-  * Record subject details 
-    * Insure that there are no contraindications for the patient completing the data collection 
-    * This may include data collection done via questionnaires or measurements 
-    * If data collection includes patient questionnaires check to make sure that they have been completed correctly 
-  * Apply markers as per experimental protocol 
-    * Take a set of digital pictures of the subject for post-hoc review of the marker placement. 
-  * Record static calibration trial 
-    * Ensure all markers are visible 
-  * Verify recorded marker set 
-    * Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol 
-  * Remove anatomical markers 
-    * If necessary, remove anatomical markers not needed for tracking in motion trials 
-  * Verify tracking using Real time 
-    * If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense 
-  * Record dynamic trials 
-  * Verify force platform assignments 
-    * Load data into Visual3D, assign movement trials to model, and verify force platform assignments 
-    * Remove assignments to partial force contacts 
-    * Remove assignments when two segments are in contact with the same platform. 
-  * Execute pipeline for creating event labels. 
-    * Verify that these event labels make intuitive sense. If not, data collection should be repeated 
- 
-====After Patient Leaves==== 
-  *  Clean up work station 
-  * Execute pipeline for processing 
-  * Load Report Template 
-  * Verify the report. 