| Visual3D streams data in real time as [[https:// | Visual3D streams data in real time as [[https:// | ||
| - | Capturing a static trial within Visual3D is especially useful when preparing for real-time digitizing or defining functional joints. | + | Capturing a static trial within Visual3D is especially useful when preparing for real-time digitizing or defining functional joints. Before starting the stream, in Nexus 2, make sure that a static |
| - | + | ||
| - | Before starting the stream, in Nexus 2, make sure that astatic | + | |
| Line 19: | Line 17: | ||
| **1. Calibrating the Capture Volume**\\ | **1. Calibrating the Capture Volume**\\ | ||
| - | * Calibrating | + | * Calibrate |
| - | **2. Verify | + | **2. Create the Session Folder**\\ |
| - | * Ensure that the appropriate session folder has been selected before capturing motion capture data. | + | * Ensure that the appropriate session folder has been selected before capturing motion capture data. Seen below, the grey circle in the Data Management indicates that the session folder is being used. |
| - | * Ensure Live mode is on before capturing data. | + | {{: |
| + | * Ensure Live Mode is enabled | ||
| + | {{: | ||
| + | * If unsure how to create the session folder, refer to [[ https:// | ||
| **3. Creating a New Subject from a Labeling Skeleton Template**\\ | **3. Creating a New Subject from a Labeling Skeleton Template**\\ | ||
| Line 31: | Line 32: | ||
| {{: | {{: | ||
| - | **4. Capture Static Calibration Trial** \\ | + | **4. Capture Static Calibration Trial (Ensure Live Mode is on)** \\ |
| * Capture a static trial. | * Capture a static trial. | ||
| + | * Return to the session folder and load the static calibration trial that was just previously captured. | ||
| **5. Reconstruct the Static Calibration Trial**\\ | **5. Reconstruct the Static Calibration Trial**\\ | ||
| - | * To reconstruct the markers, on the **Tool Bar** click the Reconstruct button or run the **Reconstruct Pipeline**. | + | * To reconstruct the markers, on the **Tool Bar** click the Reconstruct button |
| + | | ||
| **6. Auto Initialize Labeling Pipeline** \\ | **6. Auto Initialize Labeling Pipeline** \\ | ||
| + | * Select the **Auto Initialize Labeling Pipeline** in the dropdown under Current Pipeline. | ||
| * Run the first step of the pipeline individually (**Auto Label Static Frame**) to assess the labeling quality and correct any incorrect labels. | * Run the first step of the pipeline individually (**Auto Label Static Frame**) to assess the labeling quality and correct any incorrect labels. | ||
| * Once satisfied, run the following two steps in the pipeline to scale the subject and create a Vicon Labeling Skeleton file([[https:// | * Once satisfied, run the following two steps in the pipeline to scale the subject and create a Vicon Labeling Skeleton file([[https:// | ||
| Line 44: | Line 48: | ||
| **7. Verify Labeling in Live Mode**\\ | **7. Verify Labeling in Live Mode**\\ | ||
| - | * Go back to " | + | * Go back to " |
| ---- | ---- | ||
| Line 55: | Line 59: | ||
| To create the segments in Visual3D, load a static trial into Visual3D and apply a model template (.mdh).\\ | To create the segments in Visual3D, load a static trial into Visual3D and apply a model template (.mdh).\\ | ||
| - | **To load the static trial, you can either:**\\ | + | **To load the static trial:**\\ |
| **Option 1** - Load the static trial collected in Nexus during Step 1.\\ | **Option 1** - Load the static trial collected in Nexus during Step 1.\\ | ||
| **Option 2** - Collect a static trial in Visual3D.\\ | **Option 2** - Collect a static trial in Visual3D.\\ | ||
| Line 70: | Line 74: | ||
| **2. Apply the Model Template**\\ | **2. Apply the Model Template**\\ | ||
| + | * Go to **Model -> Apply Model Template** and browse to necessary model template (.mdh)\\ | ||
| {{: | {{: | ||
| Line 81: | Line 86: | ||
| **2. Define the name of the model**\\ | **2. Define the name of the model**\\ | ||
| + | * Define the name of the model template. | ||
| {{: | {{: | ||
| - | 3. Select the correct real-time system from the drop down menu and click start streaming. When prompted, specify the sampling frequency. When prompted, specify the IP address as the local host, 127.0.0.1 and port as 801. | + | **3. Verify Settings**\\ |
| + | * Select the correct real-time system from the drop down menu and click start streaming. | ||
| + | * When prompted, specify the sampling frequency. | ||
| + | * When prompted, specify the IP address as the local host, 127.0.0.1 and port as 801. | ||
| - | 4. While the subject is standing still, collect a static trial by either clicking **Create Snapshot (Static Trial)** to save the static trial in the workspace or **Save Static File to Disk** to save the static trial as a C3D file. Please note that closing the Real Time Model Building dialog box will stop the real time streaming and remove the markers from the 3D viewer. After closing this dialog, if the static trial does not appear in the 3D viewer, switch to the Workspace tab and back to the Models tab.\\ | + | **4. Collect Static Calibration Trial**\\ |
| - | {{: | + | * |
| + | * Please note that closing the Real Time Model Building dialog box will stop the real time streaming and remove the markers from the 3D viewer. After closing this dialog, if the static trial does not appear in the 3D viewer, switch to the Workspace tab and back to the Models tab.\\ | ||
| + | {{: | ||
| - | **5.** Go to **Model -> Apply Model Template** and browse to necessary model template (.mdh)\\ | + | **5. Apply the Model Template**\\ |
| + | | ||
| ---- | ---- | ||
| Line 101: | Line 113: | ||
| **3. Data Streaming in Nexus** \\ | **3. Data Streaming in Nexus** \\ | ||
| * In the dialog box the plug in will be visible %%__%%%%__%%%%__%%.dlls Click Vicon_Nexus_RT. | * In the dialog box the plug in will be visible %%__%%%%__%%%%__%%.dlls Click Vicon_Nexus_RT. | ||
| - | * A dialog box will appear to select | + | * A dialog box will appear to select |
| {{: | {{: | ||
| {{: | {{: | ||
| Line 140: | Line 152: | ||
| **Data:** LINK_MODEL_BASED:: | **Data:** LINK_MODEL_BASED:: | ||
| - | {{: | + | {{: |
| - | Your result should show a Real-Time stream that looks like the picture below | + | The result should show a Real-Time stream that looks like the picture below. |
| - | {{: | + | {{: |
| Remember to save the Graph and RT Pipeline | Remember to save the Graph and RT Pipeline | ||
| - | **It is very important that Nexus automatic labeling works properly in " | + | **Important Reminder: |