visual3d:overview:testing_setup_checklist
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| visual3d:overview:testing_setup_checklist [2024/06/19 12:54] – sgranger | visual3d:overview:testing_setup_checklist [2024/07/12 13:31] (current) – removed sgranger | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | when completing process oriented tasks, checklists are important part of the process. a thorough explanation of the benefits of checklists can be fount in [[http:// | ||
| - | |||
| - | there are many crucial steps in collecting " | ||
| - | |||
| - | the following checklist is a starting point from which motion capture laboratories can build their own. | ||
| - | |||
| - | we encourage users to contribute to this list by sending additional tasks to support@c-motion.com | ||
| - | |||
| - | ===== before patient' | ||
| - | |||
| - | ==== turn on all systems ==== | ||
| - | |||
| - | ==== verify position and orientation ==== | ||
| - | |||
| - | verify the position and orientation of motion capture cameras | ||
| - | verify the position and orientation of force platforms | ||
| - | verify the position and orientation of force structures | ||
| - | verify the position and orientation of obstacles or environment objects | ||
| - | ==== perform system calibration ==== | ||
| - | |||
| - | perform static and/or dynamic calibrations of data collection devices | ||
| - | verify results against the standards developed/ | ||
| - | ==== verify the protocol being used for the session ==== | ||
| - | |||
| - | verify the experimental protocol for the current data collection session | ||
| - | ==== set appropriate system settings ==== | ||
| - | |||
| - | as per experimental protocol, set and verify system settings | ||
| - | e.g. sampling rates (synchronise), | ||
| - | ==== zero force plates and perform caltester test ==== | ||
| - | |||
| - | perform caltester test at a minimum of 2 locations on each force platform | ||
| - | verify against prior laboratory results | ||
| - | ==== prepare necessary markers and supplies ==== | ||
| - | |||
| - | ===== patient' | ||
| - | |||
| - | ==== obtain informed consent ==== | ||
| - | |||
| - | ==== record subject details ==== | ||
| - | |||
| - | insure that there are no contraindications for the patient completing the data collection | ||
| - | this may include data collection done via questionnaires or measurements | ||
| - | if data collection includes patient questionnaires check to make sure that they have been completed correctly | ||
| - | ==== apply markers as per experimental protocol ==== | ||
| - | |||
| - | take a set of digital pictures of the subject for post-hoc review of the marker placement. | ||
| - | ==== record static calibration trial ==== | ||
| - | |||
| - | ensure all markers are visible | ||
| - | ==== verify recorded marker set ==== | ||
| - | |||
| - | verify recorded marker set by launching visual3d, creating model, and applying model template appropriate for the protocol | ||
| - | ==== remove anatomical markers ==== | ||
| - | |||
| - | if necessary, remove anatomical markers not needed for tracking in motion trials | ||
| - | ==== verify tracking using real time ==== | ||
| - | |||
| - | if you switch to the real time mode in visual3d, you can verify that the tracking markers assigned to each segment are appropriate, | ||
| - | ==== record dynamic trials ==== | ||
| - | |||
| - | ==== verify force platform assignments ==== | ||
| - | |||
| - | load data into visual3d, assign movement trials to model, and verify force platform assignments | ||
| - | remove assignments to partial force contacts | ||
| - | remove assignments when two segments are in contact with the same platform. | ||
| - | ==== execute pipeline for creating event labels. ==== | ||
| - | |||
| - | verify that these event labels make intuitive sense. if not, data collection should be repeated | ||
| - | ===== after patient leaves ===== | ||
| - | |||
| - | ==== clean up work station ==== | ||
| - | |||
| - | ==== execute pipeline for processing ==== | ||
| - | |||
| - | ==== load report template ==== | ||
| - | |||
| - | ==== verify the report. ==== | ||
| - | |||
| - | |||
visual3d/overview/testing_setup_checklist.1718801642.txt.gz · Last modified: by sgranger