 ====== Testing Setup Checklist ====== ====== Testing Setup Checklist ======
  
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]]+Checklists are important part of completing any process-oriented task. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]], this is our attempt to provide an entry-level checklist for capturing marker-based motion capture data. Of course, there are many crucial steps in collecting "routine" motion capture data and a normal collection session looks different in every lab. This checklist should be thought of as a starting point for your Motion Capture laboratory to build upon.
  
-There are many crucial steps in collecting "routine" motion capture data.+Have any suggestions? Let us know at support@has-motion.ca.
  
-The following checklist is starting point from which Motion Capture Laboratories can build their own.+**NOTE**: Interested in collecting markerless motion capture data? The [[https://smithengineering.queensu.ca/mme/research/hmrl/mmoa-wiki.html|Multi-centre & Markerless Orthopaedic Assessment Wiki]] has comprehensive overview of that study's collection and data management processes, including a [[https://queensuca.sharepoint.com/:w:/t/GROUP-HMRL/EXl-bSInaihAgiYEP2FA3mwB9STLb370wzQNzjHrvtQDVg?e=5NoQ08|day-to-day checklist]].
  
-We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca+===== Before Participant's Arrival =====
  
-===== Before Patient's Arrival =====+  - Turn on ALL systems 
 +  - Verify position and orientation of all equipment 
 +    - Verify the position and orientation of Motion Capture Cameras 
 +    - Verify the position and orientation of Force Platforms 
 +    - Verify the position and orientation of Force Structures 
 +    - Verify the position and orientation of Obstacles or Environment objects 
 +  - Perform system calibration 
 +    - Perform static and/or dynamic calibrations of data collection devices 
 +    - Verify results against the Standards developed/referenced by your laboratory 
 +  - Verify the protocol being used for the session 
 +    - Verify the experimental protocol for the current data collection session 
 +  - Ensure appropriate system settings are selected 
 +    - As per experimental protocol, set and verify system settings, e.g., synchronise sampling rates, define marker thresholds and ranges, set up triggers etc. 
 +  - Zero force plates and perform CalTester test 
 +    - Perform Caltester test at a minimum of 2 locations on each force platform 
 +    - Verify against prior laboratory results 
 +  - Prepare necessary markers and supplies
  
-====  1. Turn on ALL systems ==== +===== Participant's Arrival =====
-\\ +
-====  2. Verify Position and Orientation ==== +
-  +
-  2.1 Verify the position and orientation of Motion Capture Cameras\\ +
-  2.2 Verify the position and orientation of Force Platforms\\ +
-  2.3 Verify the position and orientation of Force Structures\\ +
-  2.4 Verify the position and orientation of Obstacles or Environment objects\\ +
-  \\ +
-====  3. Perform System Calibration ====+
  
-  3.1 Perform static and/or dynamic calibrations of data collection devices\\ +  Obtain informed consent 
-  3.2 Verify results against the Standards developed/referenced by your laboratory\\ +  Record participant details 
-  \\ +    - Ensure that there are no contraindications for the participant completing the data collection 
-====  4. Verify the protocol being used for the session ==== +    This may include data collection done via questionnaires or measurements 
- +    If data collection includes questionnairescheck to make sure that they have been completed correctly 
-  4.1 Verify the experimental protocol for the current data collection session\\ +  Apply markers as per experimental protocol 
-  \\ +    Take a set of digital pictures of the subject for post-hoc review of the marker placement 
-====  5. Set appropriate system settings ==== +  Record static calibration trial 
- +    Ensure all markers are visible during the static trial 
-  5.1 As per experimental protocol, set and verify system settings +  Verify recorded marker set 
-   * e.g. sampling rates (synchronise), marker thresholds, ranges, triggers etc.\\ +    Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol 
-\\ +  Remove anatomical markers 
-====  6. Zero Force Plates and Perform CalTester test ==== +    If necessary, remove anatomical markers not needed for tracking during dynamic motion trials 
- +  Verify tracking using real-time 
-  6.1 Perform Caltester test at a minimum of 2 locations on each force platform\\ +    - Switch to Visual3D'real-time mode in Visual3D to verify that the tracking markers assigned to each segment are appropriate and that the force vectors make intuitive sense 
-  6.2 Verify against prior laboratory results\\ +  Record dynamic trials 
-  \\ +  Verify force platform assignments 
-====  7. Prepare necessary markers and supplies ==== +    Load data into Visual3D, assign movement trials to model, and verify force platform assignments 
- +    Remove assignments to partial force contacts 
-===== Patient's Arrival ===== +    Remove assignments when two segments are in contact with the same platform 
- +  Execute pipeline for creating event labels 
-====  8. Obtain informed consent ==== +    Verify that these event labels make intuitive sense. If not, data collection should be repeated
- +
-====  9. Record subject details ==== +
- +
-  9.1 Insure that there are no contraindications for the patient completing the data collection\\ +
-   * This may include data collection done via questionnaires or measurements\\ +
-   * If data collection includes patient questionnaires check to make sure that they have been completed correctly\\ +
-\\ +
-====  10. Apply markers as per experimental protocol ==== +
- +
-  10.1 Take a set of digital pictures of the subject for post-hoc review of the marker placement\\ +
-\\ +
-====  11. Record static calibration trial ==== +
- +
-  11.1 Ensure all markers are visible\\ +
-  \\ +
-====  12. Verify recorded marker set ==== +
- +
-  12.1 Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol\\ +
-  \\ +
-====  13. Remove anatomical markers ==== +
- +
-  13.1 If necessary, remove anatomical markers not needed for tracking in motion trials\\ +
-  \\ +
-====  14. Verify tracking using Real time ==== +
- +
-  14.1 If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriateand that the force vectors make intuitive sense\\ +
-  \\ +
-====  15. Record dynamic trials ==== +
- +
-====  16. Verify force platform assignments ==== +
- +
-  16.1 Load data into Visual3D, assign movement trials to model, and verify force platform assignments\\ +
-  16.2 Remove assignments to partial force contacts\\ +
-  16.3 Remove assignments when two segments are in contact with the same platform\\ +
-  \\ +
-====  17. Execute pipeline for creating event labels ==== +
- +
-  17.1 Verify that these event labels make intuitive sense. If not, data collection should be repeated\\+
      
-===== After Patient Leaves ===== +===== After Participant Leaves =====
- +
-====  18. Clean up work station ==== +
- +
-====  19. Execute pipeline for processing ==== +
- +
-====  20. Load Report Template ==== +
- +
-====  21. Verify the report ==== +
- +
  
 +  - Clean up work station
 +  - Execute pipeline for processing
 +  - Load Report Template
 +  - Verify the report
visual3d/getting_started/testing_setup_checklist.1722004114.txt.gz · Last modified: by wikisysop