visual3d:getting_started:testing_setup_checklist [2024/07/26 14:23] wikisysopvisual3d:getting_started:testing_setup_checklist [2026/01/07 15:19] (current) – Changed section headers to list items; added markerless checklist link; removed word "patient". wikisysop
Line 1: Line 1:
 ====== Testing Setup Checklist ====== ====== Testing Setup Checklist ======
  
-When completing process oriented tasks, checklists are important part of the process. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]]+Checklists are important part of completing any process-oriented task. A thorough explanation of the benefits of checklists can be fount in [[http://gawande.com/the-checklist-manifesto|The Checklist Manifesto]], this is our attempt to provide an entry-level checklist for capturing marker-based motion capture data. Of course, there are many crucial steps in collecting "routine" motion capture data and a normal collection session looks different in every lab. This checklist should be thought of as a starting point for your Motion Capture laboratory to build upon.
  
-There are many crucial steps in collecting "routine" motion capture data.+Have any suggestions? Let us know at support@has-motion.ca.
  
-The following checklist is starting point from which Motion Capture Laboratories can build their own.+**NOTE**: Interested in collecting markerless motion capture data? The [[https://smithengineering.queensu.ca/mme/research/hmrl/mmoa-wiki.html|Multi-centre & Markerless Orthopaedic Assessment Wiki]] has comprehensive overview of that study's collection and data management processes, including a [[https://queensuca.sharepoint.com/:w:/t/GROUP-HMRL/EXl-bSInaihAgiYEP2FA3mwB9STLb370wzQNzjHrvtQDVg?e=5NoQ08|day-to-day checklist]].
  
-We encourage users to contribute to this list by sending additional tasks to support@has-motion.ca+===== Before Participant's Arrival =====
  
-===== Before Patient's Arrival ===== +  - Turn on ALL systems 
- +  Verify position and orientation of all equipment 
-====  Turn on ALL systems ==== +    Verify the position and orientation of Motion Capture Cameras 
- +    Verify the position and orientation of Force Platforms 
-====  Verify Position and Orientation ==== +    Verify the position and orientation of Force Structures 
- +    Verify the position and orientation of Obstacles or Environment objects 
-Verify the position and orientation of Motion Capture Cameras +  Perform system calibration 
-Verify the position and orientation of Force Platforms +    Perform static and/or dynamic calibrations of data collection devices 
-Verify the position and orientation of Force Structures +    Verify results against the Standards developed/referenced by your laboratory 
-Verify the position and orientation of Obstacles or Environment objects +  Verify the protocol being used for the session 
-====  Perform System Calibration ==== +    Verify the experimental protocol for the current data collection session 
- +  - Ensure appropriate system settings are selected 
-Perform static and/or dynamic calibrations of data collection devices +    As per experimental protocol, set and verify system settingse.g., synchronise sampling rates, define marker thresholds and ranges, set up triggers etc. 
-Verify results against the Standards developed/referenced by your laboratory +  Zero force plates and perform CalTester test 
-====  Verify the protocol being used for the session ==== +    Perform Caltester test at a minimum of 2 locations on each force platform 
- +    Verify against prior laboratory results 
-Verify the experimental protocol for the current data collection session +  Prepare necessary markers and supplies
-====  Set appropriate system settings ==== +
- +
-As per experimental protocol, set and verify system settings +
-e.g. sampling rates (synchronise), marker thresholdsranges, triggers etc. +
-====  Zero Force Plates and Perform CalTester test ==== +
- +
-Perform Caltester test at a minimum of 2 locations on each force platform +
-Verify against prior laboratory results +
-====  Prepare necessary markers and supplies ==== +
- +
-===== Patient's Arrival ===== +
- +
-====  Obtain informed consent ==== +
- +
-====  Record subject details ==== +
- +
-Insure that there are no contraindications for the patient completing the data collection +
-This may include data collection done via questionnaires or measurements +
-If data collection includes patient questionnaires check to make sure that they have been completed correctly +
-====  Apply markers as per experimental protocol ==== +
- +
-Take a set of digital pictures of the subject for post-hoc review of the marker placement. +
-====  Record static calibration trial ==== +
- +
-Ensure all markers are visible +
-====  Verify recorded marker set ==== +
- +
-Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol +
-====  Remove anatomical markers ==== +
- +
-If necessary, remove anatomical markers not needed for tracking in motion trials +
-====  Verify tracking using Real time ==== +
- +
-If you switch to the real time mode in Visual3D, you can verify that the tracking markers assigned to each segment are appropriate, and that the force vectors make intuitive sense +
-====  Record dynamic trials ==== +
- +
-====  Verify force platform assignments ==== +
- +
-Load data into Visual3D, assign movement trials to model, and verify force platform assignments +
-Remove assignments to partial force contacts +
-Remove assignments when two segments are in contact with the same platform. +
-====  Execute pipeline for creating event labels. ==== +
- +
-Verify that these event labels make intuitive sense. If not, data collection should be repeated +
-===== After Patient Leaves ===== +
- +
-====  Clean up work station ==== +
- +
-====  Execute pipeline for processing ==== +
- +
-====  Load Report Template ==== +
- +
-====  Verify the report. ====+
  
 +===== Participant's Arrival =====
  
 +  - Obtain informed consent
 +  - Record participant details
 +    - Ensure that there are no contraindications for the participant completing the data collection
 +    - This may include data collection done via questionnaires or measurements
 +    - If data collection includes questionnaires, check to make sure that they have been completed correctly
 +  - Apply markers as per experimental protocol
 +    - Take a set of digital pictures of the subject for post-hoc review of the marker placement
 +  - Record static calibration trial
 +    - Ensure all markers are visible during the static trial
 +  - Verify recorded marker set
 +    - Verify recorded marker set by launching Visual3D, creating model, and applying model template appropriate for the protocol
 +  - Remove anatomical markers
 +    - If necessary, remove anatomical markers not needed for tracking during dynamic motion trials
 +  - Verify tracking using real-time
 +    - Switch to Visual3D's real-time mode in Visual3D to verify that the tracking markers assigned to each segment are appropriate and that the force vectors make intuitive sense
 +  - Record dynamic trials
 +  - Verify force platform assignments
 +    - Load data into Visual3D, assign movement trials to model, and verify force platform assignments
 +    - Remove assignments to partial force contacts
 +    - Remove assignments when two segments are in contact with the same platform
 +  - Execute pipeline for creating event labels
 +    - Verify that these event labels make intuitive sense. If not, data collection should be repeated
 +  
 +===== After Participant Leaves =====
  
 +  - Clean up work station
 +  - Execute pipeline for processing
 +  - Load Report Template
 +  - Verify the report
visual3d/getting_started/testing_setup_checklist.1722003787.txt.gz · Last modified: by wikisysop