Line 24: Line 24:
 |    23.62 IN [600.0 mm]    |    15.75 IN [400.0 mm]    | |    23.62 IN [600.0 mm]    |    15.75 IN [400.0 mm]    |
  
 +===Bertec's Split-Belt Treadmill Dimensions===
  
 +Bertec's Split-Belt Treadmill **ITC-21-20 Standard Treadmill** 
  
 +The left half of the treadmill uses a coordinate system with its origin located at the inner corner of the arm block. In this setup, the Y-axis points forward, the X-axis points to the left (outward from the treadmill), and the Z-axis points downward. 
 +
 +The right half of the treadmill also has its coordinate system origin at the inner corner of the arm block. However, in this case, while the Y-axis still points forward and the Z-axis points downward, the X-axis points to the left, which is toward the center of the treadmill.
 +
 +For integration with motion capture software, the treadmill should be defined as two separate force plates, each measuring 70 inches by 22 inches (177.8 cm × 55.9 cm), with a 0.125-inch (0.32 cm) gap between them. 
  
  