visual3d:documentation:reports:text_metric_table
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| visual3d:documentation:reports:text_metric_table [2024/06/19 12:53] – sgranger | visual3d:documentation:reports:text_metric_table [2024/07/17 15:46] (current) – created sgranger | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | {{{{{{{{{{{{{{{{{{text metric table | + | ====== Text Metric Table ====== |
| - | metricreportitemdlg.jpg | + | Text Metric Table |
| - | ===== table formatting ===== | + | {{: |
| - | ==== metric table size ==== | + | ==== Table Formatting |
| - | metrictablesize.jpg | + | === Metric Table Size === |
| - | ==== cell borders ==== | + | {{: |
| - | areaborder.jpg | + | === Cell Borders === |
| - | ==== select area ==== | + | {{: |
| - | selectarea.jpg | + | === Select Area === |
| - | ==== metric fonts ==== | + | {{: |
| - | metricfonts.jpg | + | === Metric Fonts === |
| - | ===== metric table items ===== | + | {{: |
| - | ==== metric data item ==== | + | ==== Metric Table Items ==== |
| - | metricdataitem.jpg | + | === Metric Data item === |
| - | the combo box will contain a list of all text signals and metric signals in the open workspace | + | {{: |
| - | for example: | + | The combo box will contain a list of all text signals and metric signals in the open Workspace |
| - | create a text item containing the c3d parameter point units | + | For example: |
| - | [[visual3d:documentation:pipeline:pipeline_commands:set_pipeline_parameter_to_data_value|set_pipeline_parameter_to_data_value]] | + | Create a text item containing the c3d parameter POINT UNITS |
| - | /signal_types=parameters | + | |
| - | /signal_folder=point | + | [[Visual3D:Documentation:Pipeline:Pipeline_Commands:Set_Pipeline_Parameter_To_Data_Value|Set_Pipeline_Parameter_To_Data_Value]] |
| - | /signal_names=units | + | /SIGNAL_TYPES=PARAMETERS |
| - | ! /signal_components=all_components | + | /SIGNAL_FOLDER=POINT |
| - | /parameter_name=text | + | /SIGNAL_NAMES=UNITS |
| + | ! /SIGNAL_COMPONENTS=ALL_COMPONENTS | ||
| + | /PARAMETER_NAME=TEXT | ||
| **;** | **;** | ||
| - | create | + | Create |
| - | [[visual3d:documentation:pipeline:other_commands:create_text_data|create_text_data]] | + | [[Visual3D:Documentation:Pipeline:Other_Commands:Create_Text_Data|Create_Text_Data]] |
| - | /signal_name=scott | + | /SIGNAL_NAME=SCOTT |
| - | /signal_folder=test | + | /SIGNAL_FOLDER=TEST |
| - | /signal_data_value=::text | + | /SIGNAL_DATA_VALUE=::TEXT |
| **;** | **;** | ||
| - | this text signal is available in the table. | + | This Text signal is available in the Table. |
| + | |||
| + | {{: | ||
| - | metricdataitem2.jpg | + | === Subject Data Item === |
| - | ==== subject data item ==== | + | {{: |
| - | subjectdataitem.jpg | + | The edit box will contain all subject data from the current Workspace |
| - | the edit box will contain all subject data from the current workspace | + | For example, to add the Subject' |
| + | === Text Item === | ||
| - | for example, to add the subject' | + | Enter the text directly into the edit box. |
| - | ==== text item ==== | + | |
| - | enter the text directly into the edit box. | + | {{:TextItem.jpg}} |
| - | textitem.jpg | ||
| - | }}}}}}}}}}}}}}}}}} | ||
visual3d/documentation/reports/text_metric_table.1718801620.txt.gz · Last modified: by sgranger
