visual3d:documentation:reports:report_2d_graph
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:reports:report_2d_graph [2024/07/16 17:00] – removed sgranger | visual3d:documentation:reports:report_2d_graph [2025/05/05 14:46] (current) – Cleaned up page, in progress. wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Report 2D Graph ====== | ||
+ | |||
+ | 2D Graph reports allow the user to display any signal in the workspace against any other signal in the workspace (or against time). | ||
+ | |||
+ | ===== Adding a 2D Report graph ===== | ||
+ | |||
+ | To add a 2D report graph, select 2D Graph in the **Items to add** combo box and select the **Add Button**. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ===== 2D Report Graph Dialog ===== | ||
+ | |||
+ | The following dialog will appear and should be populated. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | This dialog is broken down into five sections to allow users precise control over which signals are plotted and how. | ||
+ | |||
+ | ==== Section 1: Graph Title ==== | ||
+ | |||
+ | Graph title, font selection and size. (Visual3D Version 5.0 feature) | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ==== Section 2: Graph Properties ==== | ||
+ | |||
+ | The basic graph properties | ||
+ | |||
+ | {{: | ||
+ | |||
+ | in this example, the graph will be plotted on Page 2, Column 1, Row 1 | ||
+ | |||
+ | ^ Parameter ^ Description ^ | ||
+ | |Files to Graph | The **Files to Graph** combo allows the user to select ALL_FILES or any TAG. | | ||
+ | |Line Color and Line Style | The top Line Color and Line Style refer to the signal lines drawn | | ||
+ | | Mean and Standard Deviation | In this example, the check boxes **Graph Mean** and **Graph Standard Deviation** are checked, which means that the mean and standard deviation of the signal lines selected will be computed and displayed.| | ||
+ | | Annotations | See also the associated Pipeline Command [[Visual3D: | ||
+ | |||
+ | === Annotations Editor === | ||
+ | |||
+ | {{: | ||
+ | |||
+ | - Within the Annotations Editor select **Add** to add an annotation to the graph or select **Edit** to modify an existing annotation. {{: | ||
+ | - The initial dialog for the annotation {{: | ||
+ | - Select the parameters of the annotation. | ||
+ | - If All Graphs are selected an annotation is added for every occurrence of the Event for every graph. {{: | ||
+ | - Notice the multiple vertical lines because there is an event for each graph. {{: | ||
+ | - If Average Event or Numerical Value is selected, Visual3D interprets the edit box. | ||
+ | - For example, specifying the Event label T3 {{: | ||
+ | - For example, in this case the average location of the Event is identified and drawn. {{: | ||
+ | - If Average Event or Numerical Value is selected, Visual3D interprets the edit box. | ||
+ | - For example, specifying the Time 3 {{: | ||
+ | - For example, in this case the annotation is drawn at 25% of the x-axis.. | ||
+ | |||
+ | ==== Section 3: X-Axis ==== | ||
+ | |||
+ | The signal used for the x-axis. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | In this example, time is displayed on the x-axis. | ||
+ | |||
+ | The signals in the Y-Axis properties for (File to graph and within a graph) that have occurrences of the range Range Begin to **Range End** will be drawn on the graph. | ||
+ | |||
+ | If **Intermediate Events** are selected, only ranges from **Range Begin** to **Range End** that contain the **intermediate events** will be graphed. | ||
+ | |||
+ | If Exclude sequences containing is populated, only ranges from **Range Begin** to **Range End** that do not contain the **excluded events** will be graphed | ||
+ | |||
+ | ==== Section 4: Y-Axis ==== | ||
+ | |||
+ | The signal used for the y-axis | ||
+ | |||
+ | {{: | ||
+ | |||
+ | In this example, the x-component of the Right Ankle Angle will be displayed. | ||
+ | |||
+ | The range of the graph can be specified as: | ||
+ | |||
+ | - Normalize 0% to 100% - each range of data will be scaled from 0 to 100 percent | ||
+ | - Global Min to Max - the minimum and maximum value of the signals across all ranges is computed | ||
+ | - By Explicit Setting - The user can format the graph and specify an explicit range regardless of the signals selected. | ||
+ | |||
+ | === Defining an Explicit Range === | ||
+ | |||
+ | Select a graph in the report. If the graph is selected you will see " | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Move the cursor over the selected graph, and push the right mouse button. A menu will appear. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Select Format Graph and a dialog will appear | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Select the Y Min and Y Max values and save these settings as the default. This means that these setting will be preserved in the Report Template. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ==== Section 5: Legend ==== | ||
+ | |||
+ | === Set the properties of the legend === | ||
+ | |||
+ | Move the cursor over the selected graph, and push the right mouse button. A menu will appear. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Select Format Graph and a dialog will appear | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Select the option to display the legend. | ||
+ | |||
+ | Select the button to modify the legend | ||
+ | |||
+ | {{: | ||
+ | |||
+ | The legend can be placed at the Top Left, Top Right, Bottom Left, or Bottom Right. | ||
+ | |||
+ | 1 or more of the selections of the legend text can be selected. | ||
+ | |||
+ | === Adding Custom Legend Text === | ||
+ | |||
+ | Adding the text for the Report Legend. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | If you have populated this dialog, you will not see the legend in the graph by default. | ||
+ | |||
+ | If you have entered text in the graph format dialog, you need to select the option to display text in the " | ||
+ | |||
+ | ===== Adding more signals to the Report Graph ===== | ||
+ | |||
+ | The report dialog acts on one report graph entity. | ||
+ | |||
+ | The graph that appears in the report, however, may contain many entities. | ||
+ | |||
+ | A second signal can be added to the graph in the report by adding another graph entity to the same location. Each graph entity may contain its own graph properties. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | For example, this image shows two graphs RANKLE_ANGLE and LANKLE_ANGLE located on Page 2, Column 1, Row 1. | ||
+ | |||
+ | The resulting graph contains data from the 2 signals. RANGLE_ANGLE in Red and LANKLE_ANGLE in Black, each with its own mean and standard deviation. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
visual3d/documentation/reports/report_2d_graph.1721149241.txt.gz · Last modified: 2024/07/16 17:00 by sgranger