 +====== Set Data To New Values ======
 +
 +This command replaces the following commands:
 +
 +Set_Frames_To_Zero\\
 +Set_Frames_To_New_Values\\
 +
 +
 +\\
 +
 +
 +==== Pipeline Command ====
 +
 +|**Set_Data_To_New_Values**                                                                                                                                                |
 +|**/SIGNAL_TYPES=**                                                                                   |The type of signal to be processed                                    |
 +|**/SIGNAL_NAMES=**                                                                                   |The names of the signals to be processed                              |
 +|**/SIGNAL_FOLDER=**                                                                                  |The name of the signal folder                                         |
 +|**/SIGNAL_COMPONENTS=**                                                                              |The signal components to be modified                                  |
 +|**/RESULT_SUFFIX=**                                                                                  |Optional Suffix to Add to the Result Name                             |
 +|**/RESULT_FOLDER=**                                                                                  |The Folder for the Results                                            |
 +|**/START_FRAME=\**                                                                                   |Start Frame                                                           |
 +|**/END_FRAME=**                                                                                      |End Frame                                                             |
 +|**/[[Visual3D:Documentation:C3D_Signal_Types:EVENT_LABEL_Data_Type#Event_Sequence|EVENT_SEQUENCE]]=**|A list of events (separated by "+" signs). For example, LHS+RTO       |
 +|**/[[Visual3D:Documentation:C3D_Signal_Types:EVENT_LABEL_Data_Type#Exclude_Events|EXCLUDE_EVENTS]]=**|Exclude Sequences containing these Events.                            |
 +|**/USE_POINT_RATE=**                                                                                 |(true or false) Explicitly uses the motion capture point rate.        |
 +|**/REPLACEMENT_VALUES=**                                                                             |The new signal value at each frame                                    |
 +|**/THRESHOLD_HIGH=**                                                                                 |Optional. Replace only if signal values is greater that this threshold|
 +|                                                                                                     |default=DATA_NOT_FOUND                                                |
 +|**/THRESHOLD_LOW=**                                                                                  |Optional. Replace only if signal values is greater that this threshold|
 +|                                                                                                     |default=DATA_NOT_FOUND                                                |
 +
 +**;**
 +
 +Set the frames of data from start_frame to end_frame and/or from Start Event to End Event.
 +
 +If a TARGET signal is set to DATA_NOT_FOUND, all components of the signal are set to DATA_NOT_FOUND.
 +
 +**Replacement_Value, Threshold_High, and Threshold_Low** can be Expressions
 +
 +==== Example: Using a Metric values as the low threshold ====
 +
 +{{:Set_Data_To_New_Values_Example_Dlg.jpg}}
 +
 +This example could use an expression instead of simply a metric value
 +
 +{{:Set_Data_To_New_Values_Example_Dlg2.jpg}}
 +
 +\\
 +
 +
 +==== Example: Change missing data to zero ====
 +
 +Visual3D has a special number which we refer to as DATA_NOT_FOUND.
 +
 +The actual value used internally is -999999
 +
 +The following command properties will change every occurrence of DATA_NOT_FOUND to 0
 +
 +\\
 +{{:Set_Data_To_New_Values_3.jpg}}
 +
 +
  