 +====== Replace ======
 +
 +||
 +
 +Replace data points in a signal interpolated values. This command uses the same algorithms as the interpolate command but it removes meaningless data in the specified range.
 +
 +{{:SignalProcessing_ReplaceDlg.png}}
 +
 +|**Replace**                                                                                                                                |
 +|**/Signal_Types=**    |The type of signal to be processed                                                                                    |
 +|**/Signal_Names=**    |The names of the signals to be processed                                                                              |
 +|**/Signal_Folder=**   |The name of the signal folder                                                                                         |
 +|**/Start_Frame=**     |The first frame in the range of data points.                                                                          |
 +|**/End_Frame=**       |The last frame in the range of data points.                                                                           |
 +|**/Polynomial_Order=**|The order of the polynomial used.                                                                                     |
 +|**/Num_Fit=**         |The number of frames of data before and after the "gap" that are used to calculate the coefficients of the polynomial.|
 +
 +The following example results in replacing frames 60 to 72 of the RFT1 motion capture marker (TARGET) with interpolated values using a third order polynomial interpolated using 6 frames before and 6 frames after the specified range.
 +
 +**Replace**
 +/Signal_Types=TARGET
 +/Signal_Names=RFT1
 +/Signal_Folder=ORIGINAL
 +/Start_Frame=60
 +/End_Frame=72
 +/Polynomial_Order=3
 +/Num_Fit=6
 +**;**
 +
  