 +====Overview====
 +Rectifying a signal is a simple process that involves taking the absolute value of a bipolar signal to output a unipolar version. The **Rectify** command can be used to compute the absolute value of every element of a signal for use cases that require entirely positive signals.
  
-||+Visual3D calculates signal rectification using the following formula:
  
-{{RectifyDlg.png}}+x(ti)= abs(x(ti))
  
-Rectify a signal. Takes the absolute value of every element of a signal.+A visual example of what rectified signal might look like:\\ 
 +{{:visual3d:documentation:pipeline:signal_commands:rectify_example.png|}}
  
-**Rectify** +====Pipeline Command==== 
-**/Signal_Types=** The type of signal to be processed +The **Rectify** command can be found in the Pipeline Workshop within the Signal Math folder as so:
-**/Signal_Names=** The names of the signals to be processed +
-"**/Signal_Folder=** The name of the signal folder +
-**;** +
-\\+
  
 +<code>
 +Rectify
 +! /SIGNAL_TYPES=
 +! /SIGNAL_FOLDER=ORIGINAL
 +! /SIGNAL_NAMES=
 +! /RESULT_TYPES=
 +! /RESULT_FOLDERS=PROCESSED
 +! /RESULT_NAME=
 +! /APPLY_AS_SUFFIX_TO_SIGNAL_NAME=
 +;
 +</code>
  
-\\ +====Command Parameters==== 
-Visual3D calculates signal rectification using the following formula:+The parameters that can be used to control the command are as follows: 
 +|**Signal Types**|The type of signal to be rectified| 
 +|**Signal Folder**|The name of the signal to be rectified| 
 +|**Signal Names**|The name of the signal folder| 
 +|**Result Types**|The type of the resulting signal| 
 +|**Result Folders**|The name of the resulting folder| 
 +|**Result Name**|The name of the resulting signal| 
 +|**Apply As Suffix To Signal Name**|Add a suffix to the signal name| 
 + 
 +====Command Dialog==== 
 +The command can be edited via text editor or via a dialog. The details on the command and the dialog are found below: 
 + 
 +{{:RectifyDlg.png}} 
 + 
 + 
 + 
 +====Example: Rectifying Hip Moment Signal==== 
 +This example shows how the Rectify command can be used on a hip moment signal to show only the absolute value of each component: 
 +<code> 
 +Rectify 
 +/SIGNAL_TYPES=LINK_MODEL_BASED 
 +! /SIGNAL_FOLDER=ORIGINAL 
 + /SIGNAL_NAMES=LHipMoment 
 + /RESULT_TYPES=LINK_MODEL_BASED 
 +! /RESULT_FOLDERS=PROCESSED 
 + /RESULT_NAME=LHip_Rectified 
 +! /APPLY_AS_SUFFIX_TO_SIGNAL_NAME= 
 +
 +</code>
  