 +===== Merge Data =====
 +
 +This command merges data from multiple signals into a single signal in one of two ways:
 +  - either via **APPEND_TO_END**, appending one signal to the end of another signal, or
 +  - via **MERGE_AS_NEW_COMPONENTS**, treating each original signal as a component of the new signal.
 +
 +<code>
 +Merge_Data
 +\SIGNAL_TYPES=
 +\SIGNAL_FOLDER=
 +\SIGNAL_NAMES=
 +!\COMPONENT_SEQUENCE=
 +!\RESULT_TYPES=DERIVED
 +!\RESULT_FOLDERS=PROCESSED
 +!\RESULT_NAME=
 +!\MERGE_TYPE=APPEND_TO_END
 +!\IGNORE_MISSING_SIGNALS=FALSE
 +!\PRE_CLEAR_RESULT_SIGNAL=FALSE
 +;
 +</code>
 +
 +{{:Merge_Data.png}}
 +
 +==== Parameters ====
 +
 +**COMPONENT_SEQUENCE:** if empty, all components of the signals will be used
 +
 +**MERGE_TYPE:** APPEND_TO_END or MERGE_AS_NEW_COMPONENTS
 +
 +  - APPEND_TO_END append one signal to the end of another signal
 +  - MERGE_AS_NEW_COMPONENTS treat each original signal as a component of the new signal
 +
 +**IGNORE_MISSING_SIGNALS:**
 +
 +**PRE_CLEAR_RESULT_SIGNAL:** Will delete the resulting signal prior to beginning
 +
 +==== Examples ====
 +
 +Below are some examples for using the Merge_Data command demonstrating both types of merges.
 +
 +=== Simple Example ===
 +
 +The command below will create a vector named **Vector** from 3 analog signals. This is an example of merging 3 signals into one signal.
 +
 +<code>
 +Merge_Data
 +/SIGNAL_NAMES=Analog1+Analog2+Analog3 
 +/SIGNAL_TYPES=ANALOG+ANALOG+ANALOG 
 +/SIGNAL_FOLDER=ORIGINAL+ORIGINAL+ORIGINAL 
 +/SIGNAL_COMPONENTS=0+0+0 
 +/RESULT_NAME=Vector 
 +/RESULT_TYPE=DERIVED 
 +/RESULT_FOLDER=PROCESSED 
 +/MERGE_TYPE=MERGE_AS_NEW_COMPONENTS 
 +;
 +</code>
 +
 +=== Create Global List of all Instances ===
 +
 +<code>
 +Select_Active_File
 +/FILE_NAME=ALL_FILES
 +;
 +
 +Merge_Data
 +/SIGNAL_TYPES=METRIC
 +/SIGNAL_FOLDER=PROCESSED
 +/SIGNAL_NAMES=GLOBAL::List_of_Instances+L_Ankle_Stiffness
 +/COMPONENT_SEQUENCE=ALL
 +/RESULT_TYPES=METRIC
 +! /RESULT_FOLDERS=PROCESSED
 +/RESULT_NAME=GLOBAL::List_of_Instances
 +! /MERGE_TYPE=APPEND_TO_END
 +/IGNORE_MISSING_SIGNALS=FALSE
 +/PRE_CLEAR_RESULT_SIGNAL=TRUE
 +;
 +</code>
 +
 +=== Add a column to a metric ===
 +
 +Another [[Metrics Example 3|example]] adds an indexing column to a metric (single values). This will allow the metric to be graphed.
 +
 +=== Merge for ASCII export ===
 +
 +The example found on [[Visual3D:Documentation:Pipeline:File_Commands:Export_Data_To_ASCII_File#Example_6:_Export_Concatenated_Metric_Signals|Exporting Concatenated Metric Signals]] will concatenate metrics signals prior to exporting to an ASCII file.
 +
 +When exporting, all signals are exported to separate columns in the exported file. For metric signals (e.g. signals with only one or two entries/frames) this can be inconvenient. It is not possible to concatenate the signals in the export command, but it is possible to concatenate the signals explicitly before export.
  
visual3d/documentation/pipeline/signal_commands/merge_data.1720791087.txt.gz · Last modified: 2024/07/12 13:31 by sgranger