User Tools

Site Tools


visual3d:documentation:pipeline:model_commands:get_vicon_model_metric

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2024/07/17 15:46] – created sgrangervisual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2026/06/11 19:07] (current) – [Pipeline Command] wikisysop
Line 5: Line 5:
 ===== Pipeline Command ===== ===== Pipeline Command =====
  
-**Get_Vicon_Model_Metric**+The command can be found in the **Pipeline Workshop** under **Model Building** as so 
 + 
 +<code> 
 +Get_Vicon_Model_Metric
 ! /CALIBRATION_FILE= ! /CALIBRATION_FILE=
 ! /MP_FILE_NAME= ! /MP_FILE_NAME=
 ! /METRIC_NAMES= ! /METRIC_NAMES=
-! /METRIC_VALUES+! /DEFAULT_METRIC_VALUES
-**;** +! /NAME_PREFIX=V_ 
-/Calibration_File refers to the Link Model in which the metrics will be stored +
-If Calibration_File is empty or =*, the current link model is used. + 
-/MP_File_Name refers to the Vicon MP file +</code> 
-If MP_File_Name is empty, the user is prompted for the filename. + 
-MP_File_Name refers to the full path name of the file. +====Command Parameters==== 
-/Metric_Names and /Metric_Values are optional + 
-If Metric_Names is empty or =*, all Metric_Names in the .mp file are selected +The following table shows the command parameters seen above and their descriptions: 
-If Metric_Values is populated, this is the default value of Metric_Names and is used if Metric_Names does not exist in the .MP file.+ 
 +|CALIBRATION_FILE| The Link Model in which the metrics will be stored if empty or =*, the current link model is used| 
 +|MP_FILE_NAME| The Vicon MP file ensure it is full pathname, if empty, the user is prompted for the filename  
 +|METRIC_NAMES| The names of the metric, if empty or =*, all names in the .mp file are selected | 
 +|DEFAULT_METRIC_VALUES | Default name value
 +|NAME_PREFIX| Prefix for the given name |  
 + 
 + 
 ===== Example ===== ===== Example =====
  
 Given an MP file containing the following information: Given an MP file containing the following information:
  
 +<code>
 $RKnee_Width = 150.0 $RKnee_Width = 150.0
 $RFoot_Width = 100.0 $RFoot_Width = 100.0
 $LKnee_Width = 150.0 $LKnee_Width = 150.0
 $LFoot_Width = 100.0 $LFoot_Width = 100.0
 +</code>
 +
 and the command and the command
  
-'**Get_Vicon_Model_Metric**+<code> 
 +Get_Vicon_Model_Metric
 /CALIBRATION_FILE=* /CALIBRATION_FILE=*
 /MP_FILE_NAME= /MP_FILE_NAME=
Line 35: Line 50:
 /METRIC_VALUES= /METRIC_VALUES=
 /NAME_PREFIX= /NAME_PREFIX=
-**;**+; 
 +</code> 
   * The current active model will be used.   * The current active model will be used.
   * The user will be prompted for the MP file name.   * The user will be prompted for the MP file name.
Line 41: Line 58:
   * No prefix will be added to the names.   * No prefix will be added to the names.
  
-\\ +<code> 
- +Get_Vicon_Model_Metric
- +
-**Get_Vicon_Model_Metric**+
 /CALIBRATION_FILE= /CALIBRATION_FILE=
 /MP_FILE_NAME= /MP_FILE_NAME=
Line 50: Line 65:
 /DEFAULT_METRIC_VALUES=0.5*DISTANCE(RIGHT_HIP,LEFT_HIP) /DEFAULT_METRIC_VALUES=0.5*DISTANCE(RIGHT_HIP,LEFT_HIP)
 /NAME_PREFIX= /NAME_PREFIX=
-**;**+; 
 +</code> 
   * RHip_Radius is not part of the MP file   * RHip_Radius is not part of the MP file
   * A default metric value has been provided   * A default metric value has been provided
visual3d/documentation/pipeline/model_commands/get_vicon_model_metric.1721231175.txt.gz · Last modified: by sgranger