Previous revision
visual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2024/07/16 16:59] – removed sgrangervisual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2026/06/11 19:07] (current) – [Pipeline Command] wikisysop
Line 1: Line 1:
 +====== Get Vicon Model Metric ======
 +
 +Extracting metric values from Vicon's .MP file into Visual3D Subject/Data Metrics
 +
 +===== Pipeline Command =====
 +
 +The command can be found in the **Pipeline Workshop** under **Model Building** as so
 +
 +<code>
 +Get_Vicon_Model_Metric
 +! /CALIBRATION_FILE=
 +! /MP_FILE_NAME=
 +! /METRIC_NAMES=
 +! /DEFAULT_METRIC_VALUES=
 +! /NAME_PREFIX=V_
 +;
 +
 +</code>
 +
 +====Command Parameters====
 +
 +The following table shows the command parameters seen above and their descriptions:
 +
 +|CALIBRATION_FILE| The Link Model in which the metrics will be stored if empty or =*, the current link model is used|
 +|MP_FILE_NAME| The Vicon MP file ensure it is full pathname, if empty, the user is prompted for the filename | 
 +|METRIC_NAMES| The names of the metric, if empty or =*, all names in the .mp file are selected |
 +|DEFAULT_METRIC_VALUES | Default name value|
 +|NAME_PREFIX| Prefix for the given name | 
 +
 +
 +
 +===== Example =====
 +
 +Given an MP file containing the following information:
 +
 +<code>
 +$RKnee_Width = 150.0
 +$RFoot_Width = 100.0
 +$LKnee_Width = 150.0
 +$LFoot_Width = 100.0
 +</code>
 +
 +and the command
 +
 +<code>
 +Get_Vicon_Model_Metric
 +/CALIBRATION_FILE=*
 +/MP_FILE_NAME=
 +/METRIC_NAMES=
 +/METRIC_VALUES=
 +/NAME_PREFIX=
 +;
 +</code>
 +
 +  * The current active model will be used.
 +  * The user will be prompted for the MP file name.
 +  * All 4 metric values in the MP file will be added to the model subject metrics
 +  * No prefix will be added to the names.
 +
 +<code>
 +Get_Vicon_Model_Metric
 +/CALIBRATION_FILE=
 +/MP_FILE_NAME=
 +/METRIC_NAMES=RHip_Radius
 +/DEFAULT_METRIC_VALUES=0.5*DISTANCE(RIGHT_HIP,LEFT_HIP)
 +/NAME_PREFIX=
 +;
 +</code>
 +
 +  * RHip_Radius is not part of the MP file
 +  * A default metric value has been provided
 +  * A model metric RHip_Radius will be created (or modified)
 +  * The value of the metric will be the expression 0.5*DISTANCE(RIGHT_HIP,LEFT_HIP)
 +
 +
  
visual3d/documentation/pipeline/model_commands/get_vicon_model_metric.1721149177.txt.gz · Last modified: by sgranger