visual3d:documentation:pipeline:model_commands:get_vicon_model_metric
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| visual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2024/06/19 13:38] – removed sgranger | visual3d:documentation:pipeline:model_commands:get_vicon_model_metric [2026/06/11 19:07] (current) – [Pipeline Command] wikisysop | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== Get Vicon Model Metric ====== | ||
| + | |||
| + | Extracting metric values from Vicon' | ||
| + | |||
| + | ===== Pipeline Command ===== | ||
| + | |||
| + | The command can be found in the **Pipeline Workshop** under **Model Building** as so | ||
| + | |||
| + | < | ||
| + | Get_Vicon_Model_Metric | ||
| + | ! / | ||
| + | ! / | ||
| + | ! / | ||
| + | ! / | ||
| + | ! / | ||
| + | ; | ||
| + | |||
| + | </ | ||
| + | |||
| + | ====Command Parameters==== | ||
| + | |||
| + | The following table shows the command parameters seen above and their descriptions: | ||
| + | |||
| + | |CALIBRATION_FILE| The Link Model in which the metrics will be stored if empty or =*, the current link model is used| | ||
| + | |MP_FILE_NAME| The Vicon MP file ensure it is full pathname, if empty, the user is prompted for the filename | | ||
| + | |METRIC_NAMES| The names of the metric, if empty or =*, all names in the .mp file are selected | | ||
| + | |DEFAULT_METRIC_VALUES | Default name value| | ||
| + | |NAME_PREFIX| Prefix for the given name | | ||
| + | |||
| + | |||
| + | |||
| + | ===== Example ===== | ||
| + | |||
| + | Given an MP file containing the following information: | ||
| + | |||
| + | < | ||
| + | $RKnee_Width = 150.0 | ||
| + | $RFoot_Width = 100.0 | ||
| + | $LKnee_Width = 150.0 | ||
| + | $LFoot_Width = 100.0 | ||
| + | </ | ||
| + | |||
| + | and the command | ||
| + | |||
| + | < | ||
| + | Get_Vicon_Model_Metric | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | ; | ||
| + | </ | ||
| + | |||
| + | * The current active model will be used. | ||
| + | * The user will be prompted for the MP file name. | ||
| + | * All 4 metric values in the MP file will be added to the model subject metrics | ||
| + | * No prefix will be added to the names. | ||
| + | |||
| + | < | ||
| + | Get_Vicon_Model_Metric | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | / | ||
| + | ; | ||
| + | </ | ||
| + | |||
| + | * RHip_Radius is not part of the MP file | ||
| + | * A default metric value has been provided | ||
| + | * A model metric RHip_Radius will be created (or modified) | ||
| + | * The value of the metric will be the expression 0.5*DISTANCE(RIGHT_HIP, | ||
| + | |||
| + | |||
visual3d/documentation/pipeline/model_commands/get_vicon_model_metric.1718804293.txt.gz · Last modified: by sgranger