visual3d:documentation:pipeline:model_commands:add_functional_joint_landmark
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:pipeline:model_commands:add_functional_joint_landmark [2024/06/17 18:21] – created sgranger | visual3d:documentation:pipeline:model_commands:add_functional_joint_landmark [2024/07/17 15:46] (current) – created sgranger | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | + | ====== Add Functional Joint Landmark ====== | |
- | + | ||
**This is a legacy command in Visual3D. Visual3D version 4.0 has a new interface for functional joints, and new way of specifying a functional joint landmark as part of the model template. This command should continue to work as originally implemented but it is recommended that you adopt the current approach** | **This is a legacy command in Visual3D. Visual3D version 4.0 has a new interface for functional joints, and new way of specifying a functional joint landmark as part of the model template. This command should continue to work as originally implemented but it is recommended that you adopt the current approach** | ||
Line 8: | Line 6: | ||
**Schwartz MH, Rozumalski A** (2005) A new method for estimating joint parameters from motion data. Journal of Biomechanics, | **Schwartz MH, Rozumalski A** (2005) A new method for estimating joint parameters from motion data. Journal of Biomechanics, | ||
- | [[Add_Functional_Joint_Landmark.png]] | + | {{:Add_Functional_Joint_Landmark.png}} |
**Add_Functional_Joint_Landmark** | **Add_Functional_Joint_Landmark** | ||
Line 40: | Line 38: | ||
* If no Reference Segment is specified, the landmark will be created relative to the first three REFERENCE MARKERS (e.g. a Technical Coordinate System will be created from these markers). If more than 3 REFERENCE MARKERS are specified, Visual3D will use all REFERENCE MARKERS to track the Technical Coordinate System. | * If no Reference Segment is specified, the landmark will be created relative to the first three REFERENCE MARKERS (e.g. a Technical Coordinate System will be created from these markers). If more than 3 REFERENCE MARKERS are specified, Visual3D will use all REFERENCE MARKERS to track the Technical Coordinate System. | ||
- | ==== NOTES ==== | + | === NOTES === |
The motion trials being used to identify the functional joint landmark must be [[Visual3D: | The motion trials being used to identify the functional joint landmark must be [[Visual3D: | ||
Line 54: | Line 52: | ||
If OTHER_SEGMENT_NAME is balcn, SIGNAL_TYPES, | If OTHER_SEGMENT_NAME is balcn, SIGNAL_TYPES, | ||
- | |||
- | |||
visual3d/documentation/pipeline/model_commands/add_functional_joint_landmark.1718648492.txt.gz · Last modified: 2024/06/17 18:21 by sgranger