User Tools

Site Tools


visual3d:documentation:pipeline:model_based_data_commands:model_cog_velocity

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:pipeline:model_based_data_commands:model_cog_velocity [2024/06/19 12:51] sgrangervisual3d:documentation:pipeline:model_based_data_commands:model_cog_velocity [2024/11/05 14:16] (current) – [MODEL COG VELOCITY] wikisysop
Line 1: Line 1:
-velocity of the [[visual3d:documentation:pipeline:model_based_data_commands:model_cog|model of center of gravity]]+===== Model COG Velocity =====
  
-===== reasons for no data =====+This model-based item represents the velocity of the [[visual3d:documentation:pipeline:model_based_data_commands:model_cog|Center of Gravity of the entire model]]. This center of gravity is calculated by first calculating the center of mass of each kinetic segment and then calculating the center of mass across all of the model's kinetic segments according to [[https://en.wikipedia.org/wiki/Center_of_mass|mechanical principles patterns]].
  
-the velocity of the com is calculated from the com. the com is the sum of the com of all segments in the model. if a kinetic segment is missing during one frameno com can be calculated at that frame.+To express the MODEL COG VELOCITY item in the [[visual3d:documentation:definitions:laboratory_coordinate_system|laboratory coordinate system]], choose the LAB segment as the resolution coordinate system. The Treadmill Data section of the dialog allows the user to account for the direction and speed of the treadmill's belt. 
 + 
 +{{:model_cog_vel_dialog.png}} 
 + 
 +==== Reasons for No Data ==== 
 + 
 +The velocity of the COG is calculated from the model's COG, which is the sum of the COM of all segments in the model. If a kinetic segment is missing during one frame then no COM can be calculated at that frame and [[visual3d:documentation:c3d_signal_types:data_not_found|NO_DATA]] will result. 
 + 
 +As an additional factor, the MODEL COG VELOCITY model-based item was added in Visual3D v2022. If working with older CMZ files, it is necessary to [[visual3d:documentation:pipeline:general_information:recalc_pipeline|Recalc]] before running the Compute Model Based Data command since this creates the Kinetic_Kinematic::Model::CenterOfMassVelocity signal. 
 + 
 +==== See Also ==== 
 + 
 +There is also a model-based item for [[visual3d:documentation:pipeline:model_based_data_commands:model_cog_acceleration|MODEL_COG_ACCELERATION]]. Or return to [[visual3d:documentation:visual3d_signal_types:link_model_based_data_type#kinematic_items|LINK_MODEL_BASED items]].
  
-also, the velocity of the com was added in visual3dv2022. if working with older cmz files, it is necessary to recalc before running the compute model based data command (this creates the kinetic_kinematic::model::centerofmassvelocity signal). 
  
  
  
visual3d/documentation/pipeline/model_based_data_commands/model_cog_velocity.1718801509.txt.gz · Last modified: 2024/06/19 12:51 by sgranger