visual3d:documentation:pipeline:metric_commands:metric_event_sequence_count
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
visual3d:documentation:pipeline:metric_commands:metric_event_sequence_count [2024/07/17 15:46] – created sgranger | visual3d:documentation:pipeline:metric_commands:metric_event_sequence_count [2025/09/24 14:26] (current) – [Example: Time_Interval] wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Metric Event Sequence Count ====== | ====== Metric Event Sequence Count ====== | ||
- | Creates a metric containing the number of Event Sequences. | + | ====Overview==== |
- | |< | + | **Metric Event Sequence Count** Creates a metric |
- | \\ | + | ====Pipeline Command==== |
- | \\ | + | |
+ | < | ||
+ | Metric_Event_Sequence_Count | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
- | ==== Time_Interval | + | ====Command Parameters==== |
- | **The Time_Interval parameter can be used to count the number of events that occur within a specific interval.** | + | The following table shows the command parameters and descriptions: |
+ | |||
+ | |**RESULT_METRIC_FOLDER**|**The resulting folder of the metric**| | ||
+ | |**RESULT_METRIC_NAME**|**Information about Parameter**| | ||
+ | |**TIME_INTERVAL**|**The number of event sequences which occur within a time interval**| | ||
+ | |**EVENT_SEQUENCE**|**The event sequence to search for and count**| | ||
+ | |**EXCLUDE_EVENTS**|**Don' | ||
+ | |**GENERATE_COUNT_TOTAL_IN_GLOBAL**|**Create a global count over the active files**| | ||
+ | |||
+ | ====Dialog==== | ||
+ | |||
+ | The command can be edited in a text editor or in a dialog form. To edit in the dialog pop up form either click on the **Edit** button in the pipeline workshop or double-click on the pipeline command. The dialog is shown below. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | The dialog box allows you to assign values to the command parameters outlined above. | ||
+ | |||
+ | ====Example: | ||
+ | |||
+ | The **Time_Interval** | ||
=== Command Setup === | === Command Setup === | ||
- | **If a trial is 20 seconds long, and a 5.0 second interval is specified, the result will be 4 metrics. Each metric will contain the number of event sequences which occur within each 5.0 second window.** | + | If a trial is 20 seconds long, and a 5.0 second interval is specified, the result will be 4 metrics. Each metric will contain the number of event sequences which occur within each 5.0 second window. |
- | |< | + | < |
+ | Metric_Event_Sequence_Count | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | |||
+ | {{: | ||
=== Result === | === Result === | ||
Line 23: | Line 62: | ||
|**When using a 5 second interval on a 20 second trial, the result will be four metrics (20/5).**\\ \\ (1) The first metric will contain the number of times the sequence occurs during the first 5 seconds of the trial\\ (2) The second metric will contain the number of times the sequence occurs during the 5 - 10 second interval of the trial\\ (3) The third metric will contain the number of times the sequence occurs during the 10 - 15 second interval of the trial\\ (4) The fourth metric will contain the number of times the sequence occurs during the 15 - 20 second interval of the trial\\ \\ **NOTE:** If the event sequence occurs between two intervals (LTO occurs at 4 sec and LHS occurs at 6 sec), this sequence will be included in Interval 1. | {{: | |**When using a 5 second interval on a 20 second trial, the result will be four metrics (20/5).**\\ \\ (1) The first metric will contain the number of times the sequence occurs during the first 5 seconds of the trial\\ (2) The second metric will contain the number of times the sequence occurs during the 5 - 10 second interval of the trial\\ (3) The third metric will contain the number of times the sequence occurs during the 10 - 15 second interval of the trial\\ (4) The fourth metric will contain the number of times the sequence occurs during the 15 - 20 second interval of the trial\\ \\ **NOTE:** If the event sequence occurs between two intervals (LTO occurs at 4 sec and LHS occurs at 6 sec), this sequence will be included in Interval 1. | {{: | ||
+ | ====Complex Example: Approximating Strides Using Angular Velocity Thresholds==== | ||
+ | |||
+ | As a subject moves through the gait cycle the angular velocities of their joints and limbs follow a known sequence with each stride. For this example we will identify this sequence for the right shank and use **Metric Event Sequence Count** to approximate the number of strides in a trial. | ||
+ | |||
+ | As a subject walks or runs their knees go through an alternating cycle of flexion and extension. This can be seen through many measurements, | ||
+ | |||
+ | < | ||
+ | Event_Threshold | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | |||
+ | < | ||
+ | Event_Threshold | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ! / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | |||
+ | Now, using these events we can use **Metric Event Sequence Count** to count the number of instances in which the right knee goes from flexing into extending and back again, with each of these representing one stride. | ||
+ | |||
+ | < | ||
+ | Metric_Event_Sequence_Count | ||
+ | ! / | ||
+ | / | ||
+ | ! / | ||
+ | / | ||
+ | / | ||
+ | ! / | ||
+ | ; | ||
+ | </ | ||
+ | A new folder should now be present in the **METRIC** folder containing a count of the event sequence. This number corresponds to the number of strides taken in a trial, which can be confirmed through further analysis or by watching the trial simulation. | ||
+ | {{: |
visual3d/documentation/pipeline/metric_commands/metric_event_sequence_count.1721231163.txt.gz · Last modified: 2024/07/17 15:46 by sgranger