visual3d:documentation:modeling:segments:v3d_composite_pelvis
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| visual3d:documentation:modeling:segments:v3d_composite_pelvis [2024/07/17 15:22] – sgranger | visual3d:documentation:modeling:segments:v3d_composite_pelvis [2026/06/09 21:13] (current) – Cleaned up formatting, added See Also section and links. wikisysop | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== V3D Composite Pelvis ====== | ====== V3D Composite Pelvis ====== | ||
| - | |{{: | + | The V3D_Composite pelvis refers to a pelvis segment created by C-Motion which is a variation on the [[Visual3D: |
| - | \\ | + | ===== Segment Definition ===== |
| + | {{: | ||
| - | **This pelvis was implemented in Visual3Dv5.02.17. CMO' | + | **NOTE**: |
| ==== Pelvis Origin ==== | ==== Pelvis Origin ==== | ||
| - | The Origin | + | The origin |
| ==== Pelvis Orientation ==== | ==== Pelvis Orientation ==== | ||
| The pelvis orientation is identical to the orientation of the CODA pelvis - the only difference between the two segments is the location of the origin. | The pelvis orientation is identical to the orientation of the CODA pelvis - the only difference between the two segments is the location of the origin. | ||
| + | * The (x-y) plane of the segment coordinate system is defined as the plane passing through the right and left ASIS markers, and the mid-point of the right and left PSIS markers. | ||
| + | * The x-axis is defined from the Left ASIS towards the Right ASIS. | ||
| + | * The z-axis is perpendicular to the (x-y) plane. | ||
| + | * The y-axis is then the cross product of the x-axis and z-axis. | ||
| - | The (x-y) plane of the segment coordinate system is defined as the plane passing through | + | If the markers have been placed accurately, the pelvis |
| - | **Note that the midpoint of the PSIS markers is the same point as the SACRUM marker used for the Helen Hayes pelvis. Therefore, if a Helen Hayes markers set was used for the motion capture, a V3D_Composite pelvis can be created using the SACRUM marker twice (once for the left PSIS and once for the right PSIS).** | + | **NOTE**: The midpoint of the PSIS markers is the same point as the SACRUM marker used for the Helen Hayes pelvis. Therefore, if a Helen Hayes markers set was used for the motion capture, a V3D_Composite pelvis can be created using the SACRUM marker twice (once for the left PSIS and once for the right PSIS). |
| - | The x-axis is defined from the Left ASIS towards the Right ASIS. | + | |
| - | + | ||
| - | The z-axis is perpendicular to the (x-y) plane. | + | |
| - | + | ||
| - | The y-axis is then the cross product of the x-axis and z-axis. | + | |
| - | + | ||
| - | If the markers have been placed accurately, the pelvis segment coordinate system will typically be tilted forward about 20 degrees, which is unfortunate for the calculation of the hip angle, but can be resolved using virtual segments ([[Visual3D: | + | |
| ==== Hip Joint Landmarks ==== | ==== Hip Joint Landmarks ==== | ||
| - | Estimates for the Right and Left Hip Joint Center are represented as Landmarks | + | Estimates for the Right and Left Hip Joint Center are represented as [[visual3d: |
| - | RHJC=(0.36*ASIS_Distance, | + | |
| - | LHJC=(0.36*ASIS_Distance, | + | |
| + | These estimates are adapted from the articles: | ||
| + | * Bell AL, Pederson DR, and Brand RA (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16: | ||
| + | * Bell AL, Pedersen DR, Brand RA (1990) A Comparison of the Accuracy of Several hip Center Location Prediction Methods. J Biomech. 23, 617-621. | ||
| - | These estimates are adapted from the articles | + | **NOTE**: If the ASIS markers have been placed medial or lateral to the palpated landmark because the subject is overweight or because the markers can not be placed at these locations, it is important to measure the inter-ASIS distance and enter this value into the Subject Properties TAB. |
| - | + | ||
| - | **Bell AL, Pederson DR, and Brand RA** (1989) Prediction of hip joint center location from external landmarks. Human Movement Science. 8:3-16:\\ | + | |
| - | **Bell AL, Pedersen DR, Brand RA** (1990) A Comparison of the Accuracy of Several hip Center Location Prediction Methods. J Biomech. 23, 617-621.\\ | + | |
| - | + | ||
| - | + | ||
| - | **Note that if the ASIS markers have been placed medial or lateral to the palpated landmark because the subject is overweight or because the markers can not be placed at these locations, it is important to measure the inter-ASIS distance and enter this value into the Subject Properties TAB.** | + | |
| - | + | ||
| - | \\ | + | |
| ==== Specifying the ASIS distance ==== | ==== Specifying the ASIS distance ==== | ||
| - | For some subjects the ASIS markers may be difficult to place precisely on the ASIS, so they get placed laterally. | + | The ASIS markers may be difficult to place precisely on the ASIS for some participants, so they end up getting |
| - | This results in an ASIS distance that is too big, and this directly affects the location of the Hip Landmark. | + | The ASIS distance |
| - | The ASIS distance is a [[Visual3D: | + | 1. Switch to the Model Metrics Tab: |
| - | + | ||
| - | Switch to the Model Metrics Tab: | + | |
| {{: | {{: | ||
| - | Select the ASIS_Distance item and select the Modify button | + | 2. Select the ASIS_Distance item and select the Modify button |
| {{: | {{: | ||
| - | Enter the measured value of the ASIS distance. | + | 3. Enter the measured value of the ASIS distance. |
| {{: | {{: | ||
| - | The hip landmark will be based on this ASIS distance. | + | 4. The hip landmark will be based on this ASIS distance. |
| + | |||
| + | ===== See Also ===== | ||
| + | Alternative pelvis segment definitions include: | ||
| + | * [[visual3d: | ||
| + | * [[visual3d: | ||
| + | * [[visual3d: | ||
| + | * Visual3D Composite Pelvis (this definition) | ||
visual3d/documentation/modeling/segments/v3d_composite_pelvis.1721229767.txt.gz · Last modified: by sgranger