User Tools

Site Tools


visual3d:documentation:modeling:segments:create_coda_pelvis_relative_to_anatomical_landmarks

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
visual3d:documentation:modeling:segments:create_coda_pelvis_relative_to_anatomical_landmarks [2024/07/17 15:22] sgrangervisual3d:documentation:modeling:segments:create_coda_pelvis_relative_to_anatomical_landmarks [2026/06/09 21:22] (current) – Cleaned up section levels and added links. wikisysop
Line 1: Line 1:
-====== Create CODA pelvis relative to anatomical landmarks ======+====== How to create a CODA pelvis relative to anatomical landmarks ======
  
-Create CODA pelvis relative to anatomical landmarks.+The [[visual3d:documentation:modeling:coordinate_system|segment coordinate system]] for the [[visual3d:documentation:modeling:segments:coda_pelvis|CODA pelvis]] is the mid-point between the ASIS markers. The anatomical landmarks are actually posterior to the ASIS markers because the motion capture system tracks the centre of the marker.
  
-The segment coordinate system for the CODA pelvis is the mid-point between the ASIS markers. The anatomical landmarks are actually posterior to the ASIS markers because the motion capture system tracks the center of the marker.+===== Correcting the CODA definition =====
  
 This is a modest error, but it can be corrected by creating landmarks that are posterior to the ASIS markers by the radius of the motion capture marker. This is a modest error, but it can be corrected by creating landmarks that are posterior to the ASIS markers by the radius of the motion capture marker.
  
-=== Step 1. Confirm the subject metric containing the marker radius===+==== Step 1. Confirm the subject metric containing the marker radius ====
  
-If the metric doesn't exist, create a new metric. +If the metric doesn't exist, create a new metric. Switch to **Subject Data/Metrics** TAB.
- +
-Switch to **Subject Data/Metrics** TAB. +
- +
-{{:SegmentExample4_1.png}}\\+
  
 +{{:SegmentExample4_1.png}}
  
 Select **Add New Item** and enter in the name **Marker_Radius** and the value. Select **Add New Item** and enter in the name **Marker_Radius** and the value.
  
-{{:SegmentExample4_2.png}}\\ +{{:SegmentExample4_2.png}}
- +
- +
-In this example, the marker has a diameter of 1.2 cm. Visual3D uses MKS units, so the value is 0.006 meters. +
- +
-**Note:** If the radius is not consistent with your marker radius, modify the value. +
- +
-=== Step 2. Create landmarks for the ASIS markers === +
- +
-{{:SegmentExample4_4.png}}\\ +
  
-**Note:** the ML Edit box contains the expression **-MARKER_RADIUS**+In this example, the marker has a diameter of 1.2 cm. Visual3D uses [[visual3d:documentation:pipeline:model_based_data_commands:units_of_measurement|MKS units]], so the value is 0.006 meters. **NOTE**: If the radius is not consistent with your marker radius, modify the value.
  
-{{:SegmentExample4_5.png}}\\+==== Step 2Create landmarks for the ASIS markers ====
  
 +{{:SegmentExample4_4.png}} {{:SegmentExample4_5.png}}
  
-**Note:** the ML Edit box contains the expression **-MARKER_RADIUS**+**NOTE**the Medial-Lateral (MLEdit box contains the [[visual3d:documentation:pipeline:expressions:expressions_overview|expression]] **-MARKER_RADIUS** to define the offset.
  
-=== Step 3. Create a CODA Pelvis ===+==== Step 3. Create a CODA Pelvis ====
  
-{{:SegmentExample4_6.png}}\\+Follow the usual steps to create a CODA pelvis segment.
  
 +{{:SegmentExample4_6.png}}
  
 In this example, the locations defining the segment coordinate system for the pelvis are the landmarks **RT_ASIS** and **LT_ASIS**, and the marker **SACR** located at the midpoint of the PSIS markers. In this example, the locations defining the segment coordinate system for the pelvis are the landmarks **RT_ASIS** and **LT_ASIS**, and the marker **SACR** located at the midpoint of the PSIS markers.
Line 46: Line 35:
 The tracking markers are **RASI**, **LASI**, and **SACR**. The tracking markers are **RASI**, **LASI**, and **SACR**.
  
-{{:SegmentExample4_7.png}}\\+{{:SegmentExample4_7.png}}
  
  
  
  
visual3d/documentation/modeling/segments/create_coda_pelvis_relative_to_anatomical_landmarks.1721229763.txt.gz · Last modified: by sgranger