| - | ====== Marker-Based Motion Capture Overview | + | ====== Marker-Based Motion Capture Overview ====== |
| + | Marker-based motion capture systems can be split into passive and active systems. | ||
| + | |||
| + | **Passive marker-based systems** generally use retroreflective markers placed on the body in accordance with a particular marker set. Cameras are set up to record the near infrared light reflected by these markers and estimate the 3-dimensional position of these markers throughout the movement. A model, essentially a mapping from markers to the skeleton, provides these marker positions with biomechanical meaning and is defined by the user. This model is applied to the recorded 3D marker positions during dynamic movements of interest to produce pose estimates. | ||
| + | |||
| + | **Active marker-based systems** generally use markers that emit light, which are placed on the body. Cameras record the light emitted by these markers and estimate their 3-dimensional position throughout the movement. | ||
| ===== Marker Sets ===== | ===== Marker Sets ===== | ||
| - | Before data collection using markerbased | + | Before data collection using marker-based |
| In general, the marker set will comprise of: | In general, the marker set will comprise of: | ||
| Line 12: | Line 18: | ||
| // Fig. 1. Visual of anatomical and tracking markers on a left tibia. The segment coordinate system is defined at the proximal end of the segment // | // Fig. 1. Visual of anatomical and tracking markers on a left tibia. The segment coordinate system is defined at the proximal end of the segment // | ||
| + | Marker sets commonly fall into three families: | ||
| + | - Plug-in Gait ([[visual3d: | ||
| + | - IOR Gait ([[other: | ||
| + | - OptiTrack ([[visual3d: | ||
| - | Some common marker sets include: | ||
| - | * The [[visual3d: | ||
| - | * The [[visual3d: | ||
| - | * The [[visual3d: | ||
| - | * The [[visual3d: | ||
| ===== Data Collection ===== | ===== Data Collection ===== | ||
| - | A [[visual3d: | + | A [[visual3d: |
| ===== Model Building ===== | ===== Model Building ===== | ||
| Line 62: | Line 67: | ||
| To visualize your motion data, check out the [[visual3d: | To visualize your motion data, check out the [[visual3d: | ||
| - | |||
| - | ===== In Addition to Marker-Based MOCAP ===== | ||
| - | ==== Forces ==== | ||
| - | If you collected force data along with your markerbased data, you can [[visual3d: | ||
| - | |||
| - | ==== EMG ==== | ||
| - | Another method of biomechanical data collection is [[visual3d: | ||