other:inspect3d:tutorials:clean_your_data [2025/01/16 19:20] wikisysopother:inspect3d:tutorials:clean_your_data [2025/01/16 19:33] (current) wikisysop
Line 88: Line 88:
  
  
-3. When Inspect3D tries to plot [[Other:Inspect3D:Documentation:Troubleshooting#Data_Missing_Graph|missing data]], your y-axis will go to -999 999.0 and the axis scale will cause the data to be compressed into lines. To avoid this, open the {{:I3DShowOptions.png}} **[[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Plotting_options|Options]]** dialog and deselect the **Show data not found** checkbox in the **Plotting options** section.+3. When Inspect3D tries to plot [[Other:Inspect3D:Documentation:Troubleshooting#Data_Missing_Graph|missing data]], your y-axis will go to -999 999.0 and the axis scale will cause the data to be compressed into lines. To avoid this, open the {{:I3DShowOptions.png?20}} **[[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Plotting_options|Options]]** dialog and deselect the **Show data not found** checkbox in the **Plotting options** section.
  
 3.1. Update your plot by clicking **Refresh Plot**; it should now resemble the graph below. 3.1. Update your plot by clicking **Refresh Plot**; it should now resemble the graph below.
Line 119: Line 119:
 {{:Inspect3D_Excluded_Traces_Shown_Four_Subjects_Walking.png}} {{:Inspect3D_Excluded_Traces_Shown_Four_Subjects_Walking.png}}
  
 +{{ :Inspect3D_Animate_Trace_Four_Subjects_Walking.png?350}}
  
-5. +5.Traces can also be examined more closely before deciding to include or exclude them.
-{{:Inspect3D_Animate_Trace_Four_Subjects_Walking.png}}+
  
-Traces can also be examined more closely before deciding to include or exclude them. 
 5.1 Select the traces of interest by clicking and dragging on the plot. 5.1 Select the traces of interest by clicking and dragging on the plot.
  
Line 132: Line 131:
 6. Once all of the desired exclusions have been made, the original data is ready to be updated. 6. Once all of the desired exclusions have been made, the original data is ready to be updated.
  
 +\\
 +\\
  
 +\\
 +\\
 ==== Updating the original data ==== ==== Updating the original data ====
 +{{ :Inspect3D_Update_CMZ_Four_Subjects_Walking.png?350}}
 +1.Now that the incorrect force assignments have been identified in our data set, it is possible to update the original [[Visual3D:Documentation:Definitions:CMO_Library_|CMZ]] data by clicking the {{:I3DUpdateCMOsWithBadEvents.png?20}} **UpdateCMZs** item in the application's tool bar. This opens a dialog that provides different options for processing excluded data.
  
-1. 
-{{:Inspect3D_Update_CMZ_Four_Subjects_Walking.png}} 
- 
-Now that the incorrect force assignments have been identified in our data set, it is possible to update the original [[Visual3D:Documentation:Definitions:CMO_Library_|CMZ]] data by clicking the {{:I3DUpdateCMOsWithBadEvents.png?20}} **UpdateCMZs** item in the application's tool bar. This opens a dialog that provides different options for processing excluded data. 
 2. The **Excluded Traces** options allow the user to add a BAD event to the excluded traces. This option is helpful if the intention is to [[Visual3D:Documentation:Definitions:Tag|tag]] the bad data, re-open the original data, and make manual corrections one trace at a time. 2. The **Excluded Traces** options allow the user to add a BAD event to the excluded traces. This option is helpful if the intention is to [[Visual3D:Documentation:Definitions:Tag|tag]] the bad data, re-open the original data, and make manual corrections one trace at a time.
  