User Tools

Site Tools


other:inspect3d:tutorials:clean_your_data

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
other:inspect3d:tutorials:clean_your_data [2025/01/16 19:11] wikisysopother:inspect3d:tutorials:clean_your_data [2025/01/16 19:33] (current) wikisysop
Line 88: Line 88:
  
  
-3. When Inspect3D tries to plot [[Other:Inspect3D:Documentation:Troubleshooting#Data_Missing_Graph|missing data]], your y-axis will go to -999 999.0 and the axis scale will cause the data to be compressed into lines. To avoid this, open the {{:I3DShowOptions.png}} **[[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Plotting_options|Options]]** dialog and deselect the **Show data not found** checkbox in the **Plotting options** section.+3. When Inspect3D tries to plot [[Other:Inspect3D:Documentation:Troubleshooting#Data_Missing_Graph|missing data]], your y-axis will go to -999 999.0 and the axis scale will cause the data to be compressed into lines. To avoid this, open the {{:I3DShowOptions.png?20}} **[[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Plotting_options|Options]]** dialog and deselect the **Show data not found** checkbox in the **Plotting options** section.
  
 3.1. Update your plot by clicking **Refresh Plot**; it should now resemble the graph below. 3.1. Update your plot by clicking **Refresh Plot**; it should now resemble the graph below.
  
-{{:Inspect3D_Queried_Data_(Four_Subjects_Walking).png}}+{{:Inspect3D_Queried_Data_Four_Subjects_Walking.png}}
  
  
 4. Use your cursor to select only lines on the graph that you wish to inspect. Click on single traces in order to examine individual curves without the other curves 'polluting' the graph. When a trace is clicked, a tooltip will appear to describe the source of the trace in terms of both Inspect3D's groups and workspaces and the underlying .c3d files. 4. Use your cursor to select only lines on the graph that you wish to inspect. Click on single traces in order to examine individual curves without the other curves 'polluting' the graph. When a trace is clicked, a tooltip will appear to describe the source of the trace in terms of both Inspect3D's groups and workspaces and the underlying .c3d files.
  
-{{:Inspect3D_Select_Trace_(Four_Subjects_Walking).png}}+{{:Inspect3D_Select_Trace_Four_Subjects_Walking.png}}
  
  
Line 113: Line 113:
 3.1 When traces are excluded, two notable differences should appear in the Queried Data subwindow. First, the previously selected, but now excluded data should not be visible on the graph. Second, the **Workspaces** widget will indicate when traces have been excluded. Specifically, an X should replace the original check mark beside each workspace where signal traces have been excluded, two horizontal bars should replace the check mark beside each .c3d file with excluded traces, and a red X should replace the checkmark beside each excluded trace. Additionally, the fraction of traces excluded for each workspace is displayed on the right-hand side of the **Workspaces** widget: in this case all of the workspaces contained poor quality events. If unintentional exclusion occurred for a subject, you can right click on the subject and select 'Re-Include Data'. 3.1 When traces are excluded, two notable differences should appear in the Queried Data subwindow. First, the previously selected, but now excluded data should not be visible on the graph. Second, the **Workspaces** widget will indicate when traces have been excluded. Specifically, an X should replace the original check mark beside each workspace where signal traces have been excluded, two horizontal bars should replace the check mark beside each .c3d file with excluded traces, and a red X should replace the checkmark beside each excluded trace. Additionally, the fraction of traces excluded for each workspace is displayed on the right-hand side of the **Workspaces** widget: in this case all of the workspaces contained poor quality events. If unintentional exclusion occurred for a subject, you can right click on the subject and select 'Re-Include Data'.
  
-{{:Inspect3D_Excluded_Traces_(Four_Subjects_Walking).png}}+{{:Inspect3D_Excluded_Traces_Four_Subjects_Walking.png}}
  
 4. If you want to visualize the data you have excluded alongside the remaining data, go to the [[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue|Show Options]] dialog and select the "Show excluded data" option. You can choose to use a specific line style for excluded data and specify this style in the [[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Line_Style|Line Styles]] tab. 4. If you want to visualize the data you have excluded alongside the remaining data, go to the [[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue|Show Options]] dialog and select the "Show excluded data" option. You can choose to use a specific line style for excluded data and specify this style in the [[Other:Inspect3D:Documentation:Dialogs:Load_Library_Dialogue#Line_Style|Line Styles]] tab.
  
-{{:Inspect3D_Excluded_Traces_Shown_(Four_Subjects_Walking).png}}+{{:Inspect3D_Excluded_Traces_Shown_Four_Subjects_Walking.png}}
  
 +{{ :Inspect3D_Animate_Trace_Four_Subjects_Walking.png?350}}
  
-5. +5.Traces can also be examined more closely before deciding to include or exclude them.
-{{:Inspect3D_Animate_Trace_(Four_Subjects_Walking).png}}+
  
-Traces can also be examined more closely before deciding to include or exclude them. 
 5.1 Select the traces of interest by clicking and dragging on the plot. 5.1 Select the traces of interest by clicking and dragging on the plot.
  
-5.2 Click the {{:I3DShowAnimation.png}} **Show Animation** button.+5.2 Click the {{:I3DShowAnimation.png?20}} **Show Animation** button.
  
 5.3 The Show Animation dialog can display animations for those selected traces with enough data in the .cmz file to permit a recreation. Each of the selected traces can be selected from the drop-down box near the top of the dialog. This view can be used to determine what (if any) issue exists in the data and whether this merits exclusions. Excluded traces are removed from the drop-down box within the dialog as well as the Queried Data subwindow. 5.3 The Show Animation dialog can display animations for those selected traces with enough data in the .cmz file to permit a recreation. Each of the selected traces can be selected from the drop-down box near the top of the dialog. This view can be used to determine what (if any) issue exists in the data and whether this merits exclusions. Excluded traces are removed from the drop-down box within the dialog as well as the Queried Data subwindow.
Line 132: Line 131:
 6. Once all of the desired exclusions have been made, the original data is ready to be updated. 6. Once all of the desired exclusions have been made, the original data is ready to be updated.
  
 +\\
 +\\
  
 +\\
 +\\
 ==== Updating the original data ==== ==== Updating the original data ====
 +{{ :Inspect3D_Update_CMZ_Four_Subjects_Walking.png?350}}
 +1.Now that the incorrect force assignments have been identified in our data set, it is possible to update the original [[Visual3D:Documentation:Definitions:CMO_Library_|CMZ]] data by clicking the {{:I3DUpdateCMOsWithBadEvents.png?20}} **UpdateCMZs** item in the application's tool bar. This opens a dialog that provides different options for processing excluded data.
  
-1. 
-{{:Inspect3D_Update_CMZ_(Four_Subjects_Walking).png}} 
- 
-Now that the incorrect force assignments have been identified in our data set, it is possible to update the original [[Visual3D:Documentation:Definitions:CMO_Library_|CMZ]] data by clicking the {{:I3DUpdateCMOsWithBadEvents.png}} **UpdateCMZs** item in the application's tool bar. This opens a dialog that provides different options for processing excluded data. 
 2. The **Excluded Traces** options allow the user to add a BAD event to the excluded traces. This option is helpful if the intention is to [[Visual3D:Documentation:Definitions:Tag|tag]] the bad data, re-open the original data, and make manual corrections one trace at a time. 2. The **Excluded Traces** options allow the user to add a BAD event to the excluded traces. This option is helpful if the intention is to [[Visual3D:Documentation:Definitions:Tag|tag]] the bad data, re-open the original data, and make manual corrections one trace at a time.
  
other/inspect3d/tutorials/clean_your_data.1737054694.txt.gz · Last modified: 2025/01/16 19:11 by wikisysop