+ | ====== 3D Calibration ====== | ||
+ | |||
+ | The //3D Calibration// | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ^ Parameter ^ Description ^ | ||
+ | | **Image Distance Allowance** | Used when calculating the 3D configuration parameters. It is the amount by which the source-to-image-plane distance is allowed to change from the user-specified value. The default value is 0.0.| | ||
+ | | **Optimize Pixel Size** | Specifies whether or not to optimize the pixel size when calculating the 3D configuration parameters. The default value is false (box is unchecked). | | ||
+ | | **Square Pixels** | Specifies whether or not to force the X and Y pixel sizes to be the same when distortion-correcting the X-ray images. The default value is true (box is checked).| | ||
+ | | **Source To Image** | The distance between the X-ray source and the plane of the image intensifier or flat-panel detector. This distance should be measured carefully in millimeters during data collection, and entered into the subject file with [[Other: | ||
+ | |||
+ | ===== See Also ===== | ||
+ | |||