other:dsx:calibratedsx:3d_calibration
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
other:dsx:calibratedsx:3d_calibration [2024/07/12 13:55] – created sgranger | other:dsx:calibratedsx:3d_calibration [2025/02/15 05:56] (current) – Cleaned up page and added backlink to widgets overview. wikisysop | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
The //3D Calibration// | The //3D Calibration// | ||
- | {{CalDSX_3DCalibrationWidget.png}} | + | {{:CalDSX_3DCalibrationWidget.png}} |
+ | ^ Parameter ^ Description ^ | ||
+ | | **Image Distance Allowance** | Used when calculating the 3D configuration parameters. It is the amount by which the source-to-image-plane distance is allowed to change from the user-specified value. The default value is 0.0.| | ||
+ | | **Optimize Pixel Size** | Specifies whether or not to optimize the pixel size when calculating the 3D configuration parameters. The default value is false (box is unchecked). | | ||
+ | | **Square Pixels** | Specifies whether or not to force the X and Y pixel sizes to be the same when distortion-correcting the X-ray images. The default value is true (box is checked).| | ||
+ | | **Source To Image** | The distance between the X-ray source and the plane of the image intensifier or flat-panel detector. This distance should be measured carefully in millimeters during data collection, and entered into the subject file with [[Other: | ||
+ | ===== See Also ===== | ||
- | * **Image Distance Allowance** Used when calculating the 3D configuration parameters. It is the amount by which the source-to-image-plane distance is allowed to change from the user-specified value. The default value is 0.0. | + | Go back to an overview |
- | + | ||
- | + | ||
- | + | ||
- | * **Optimize Pixel Size** Specifies whether or not to optimize the pixel size when calculating the 3D configuration parameters. The default value is false (box is unchecked). | + | |
- | + | ||
- | + | ||
- | + | ||
- | * **Square Pixels** Specifies whether or not to force the X and Y pixel sizes to be the same when distortion-correcting the X-ray images. The default value is true (box is checked). | + | |
- | + | ||
- | + | ||
- | + | ||
- | * **Source To Image** The distance between the X-ray source and the plane of the image intensifier or flat-panel detector. This distance should be measured carefully in millimeters during data collection, and entered into the subject file with [[Other:DSX:xManager:xManager_Overview|// | + | |
- | + | ||
other/dsx/calibratedsx/3d_calibration.1720792526.txt.gz · Last modified: 2024/07/12 13:55 by sgranger