| + | ====== Installation | ||
| + | |||
| + | \\ | ||
| + | |||
| + | |||
| + | ==== Downloading AMASS ==== | ||
| + | |||
| + | C-Motion software is all downloaded over the Internet at [[https:// | ||
| + | Customers are provided login information to access the download page.\\ | ||
| + | \\ | ||
| + | After you log in at [[https:// | ||
| + | \\ | ||
| + | {{: | ||
| + | \\ | ||
| + | |||
| + | |||
| + | - Click the **DOWNLOAD** Buttons to save the AMASS installation files to your computer. | ||
| + | |||
| + | \\ | ||
| + | Most web browsers will offer you a choice of where to save the downloaded file. Make sure you remember where you save the downloaded file. | ||
| + | |||
| + | Run the installation executable file you downloaded. | ||
| + | |||
| + | \\ | ||
| + | |||
| + | |||
| + | ==== Install NaturalPoint SDK ==== | ||
| + | |||
| + | If you intend to use Natural Point cameras, please download the Optitrack SDK [[http:// | ||
| + | |||
| + | ==== The AMASS Wand ==== | ||
| + | |||
| + | An AMASS calibration wand must be used to perform the calibration. It is a tensioned cable on which is mounted six markers spaced more or less evenly. | ||
| + | |||
| + | [[File: | ||
| + | |||
| + | **NOTE** If AMASS reports that the Wand is not recognized when calibrating, | ||
| + | |||
| + | [[Other: | ||
| + | |||
| + | ==== Visual3D ==== | ||
| + | |||
| + | **DOWNLOAD** and install Visual3D if appropriate. Instructions are [[Visual3D: | ||
| + | |||
| + | ==== Configure AMASS ==== | ||
| + | |||
| + | AMASS configuration shortcut - If using the NaturalPoint L-Frame, copy the .ref file from the tutorials sample to your own working directory (i.e. the place you will be saving motion capture files). Here is another copy [[https:// | ||
| + | |||
| + | \\ | ||
| + | Start AMASS, create an initial Project. Click on the AMASS program icon in the desktop to start the AMASS shell program. | ||
| + | |||
| + | //Note: AMASS starts and loads the last project it was working on. If there was no previous project, or it was moved, then the following screen appears.// | ||
| + | |||
| + | {{:a1.png}} | ||
| + | |||
| + | For a new installation, | ||
| + | |||
| + | ==== Project Control ==== | ||
| + | |||
| + | Enter a file name (i.e. something like " | ||
| + | |||
| + | Set the Folder box in the bottom of the screen to the directory where you will be saving data. | ||
| + | |||
| + | \\ | ||
| + | Project Tabs - Here are some standard settings... | ||
| + | |||
| + | === Input Tab === | ||
| + | |||
| + | This tab set AMASS input data format options. | ||
| + | |||
| + | * Input system = Capture (multiple input files formats are supported. Capture2D is the program used for NaturalPoint cameras. Other input sources are also supported.) | ||
| + | * ViewCen = Checked (to view centroids meaning to actually see the targets/ | ||
| + | |||
| + | {{:a3.png}} | ||
| + | |||
| + | === Calibrate Tab === | ||
| + | |||
| + | This tab set AMASS volume calibration options. No need to change anything unless the file location changed. | ||
| + | |||
| + | * Cameras to use = All checked (This option allow you to disable input from specific cameras) | ||
| + | * Reference marker file = C:\[your directory]\L_Frame.ref. | ||
| + | |||
| + | Click **Browse…** and navigate to select the file you want. This file identifies your L-Frame and where the markers are located on it. The sample is for a NaturalPoint frame. | ||
| + | |||
| + | {{:a4.png}} | ||
| + | |||
| + | === Track Tab === | ||
| + | |||
| + | This tab set AMASS target tracking options. | ||
| + | |||
| + | * Calibration file = BLANK (you haven' | ||
| + | |||
| + | This is not critical, since if you create a new calibration file (or run the tutorial) when you click an " | ||
| + | |||
| + | {{:a5.png}} | ||
| + | |||
| + | === Identify Tab === | ||
| + | |||
| + | This tab set AMASS target naming and identification options. You likely do not have a marker file. when you go to identify your first set of targets, save the marker names you use and this entry will automatically be updated. | ||
| + | |||
| + | * Marker file = can be blank. If it is something else, click Browse… and then navigate to select your .mkr file. | ||
| + | * Link File = can be blank. It is unused now, but will be needed for the automatic tracking feature (coming soon) | ||
| + | |||
| + | {{:a6.png}} | ||
| + | |||
| + | \\ | ||
| + | Click **OK** to close the AMASS Parameters/ | ||
| + | |||
| + | \\ | ||
| + | You are now ready to collect data! | ||
| + | |||
| + | Turn on your cameras and click the Capture2D button. | ||
| + | |||
| + | |||
other/amass/tutorials/installation.1719432834.txt.gz · Last modified: by sgranger