User Tools

Site Tools


caltester:caltesterplus:tutorials:platform

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
caltester:caltesterplus:tutorials:platform [2024/06/18 13:22] sgrangercaltester:caltesterplus:tutorials:platform [2024/07/17 15:44] (current) – created sgranger
Line 1: Line 1:
-====== Collecting CalTester Data ======+====== Platform ====== 
 + 
 +===== Collecting CalTester Data =====
  
 In order to use the CalTesterPlus program you need a set of properly collected data for each force platform you wish to calibrate. To collect a useful motion trial for the report mode follow the following process. In order to use the CalTesterPlus program you need a set of properly collected data for each force platform you wish to calibrate. To collect a useful motion trial for the report mode follow the following process.
  
-===== Static Trials =====+==== Static Trials ====
  
   - Set up your capture volume making sure that all force platforms and cameras are in the positions that they will remain in for following data collections.   - Set up your capture volume making sure that all force platforms and cameras are in the positions that they will remain in for following data collections.
Line 16: Line 18:
   * Each example motion trial that is downloaded with the CalTesterPlus program meets these criteria.   * Each example motion trial that is downloaded with the CalTesterPlus program meets these criteria.
  
-====== Compute Platform Pose ======+===== Compute Platform Pose =====
  
 Computing the Platform Pose gives you a written report of the force platform's optimal location in your lab. This report can be saved as a text file and the values can be inputted into the data collection software that you use. You can either complete this tutorial using data you have collected in your own lab following the guide lines above, or by using the sample data that was provided when you installed CalTesterPlus. This sample data can be found on the following file path: C:\Program Files\C-Motion\CalTesterPlus\Samples\TutorialFiles Computing the Platform Pose gives you a written report of the force platform's optimal location in your lab. This report can be saved as a text file and the values can be inputted into the data collection software that you use. You can either complete this tutorial using data you have collected in your own lab following the guide lines above, or by using the sample data that was provided when you installed CalTesterPlus. This sample data can be found on the following file path: C:\Program Files\C-Motion\CalTesterPlus\Samples\TutorialFiles
Line 22: Line 24:
 **1. Use the add button at the top right-hand side of the screen to load all of the .c3d files that you want to use to create a report from, and select them by highlighting them. For the sample data we will be using the files "TrialBack1.c3d" through to "TrialBack11.c3d".** **1. Use the add button at the top right-hand side of the screen to load all of the .c3d files that you want to use to create a report from, and select them by highlighting them. For the sample data we will be using the files "TrialBack1.c3d" through to "TrialBack11.c3d".**
  
-{{PlatformTutorial1.png}}+{{:PlatformTutorial1.png}}
 **2. Make sure that you are on the Platform tab at the bottom section of the screen.**\\ **2. Make sure that you are on the Platform tab at the bottom section of the screen.**\\
 (A) Check that you have selected the force platform number that corresponds to the force platform that the CalTester Rod was used on. If you are using the sample data it is FP 1.\\ (A) Check that you have selected the force platform number that corresponds to the force platform that the CalTester Rod was used on. If you are using the sample data it is FP 1.\\
Line 31: Line 33:
  
  
-{{PlatformTutorial2.png}}+{{:PlatformTutorial2.png}}
 **3. Check the CalTester rod labels:**\\ **3. Check the CalTester rod labels:**\\
 (A) If the CalTester rod is not already labeled click the Guess Combinations button.\\ (A) If the CalTester rod is not already labeled click the Guess Combinations button.\\
 (B) Verify that the CalTester Rod has been appropriately labeled. The proper labeling for the sample data is shown below. The Save Combination as Default button can be used if this is a naming convention that you will be reusing. (B) Verify that the CalTester Rod has been appropriately labeled. The proper labeling for the sample data is shown below. The Save Combination as Default button can be used if this is a naming convention that you will be reusing.
  
-{{PlatformTutorial4.png}}+{{:PlatformTutorial4.png}}
 **5. Check that the dimensions of the CalTester Rod are correct.** **5. Check that the dimensions of the CalTester Rod are correct.**
  
 If you are using the sample data or the CalTester Rod manufactured by [[http://www.motion-labs.com/|Motion Lab Systems]] use the values that are specified below. If you are using the sample data or the CalTester Rod manufactured by [[http://www.motion-labs.com/|Motion Lab Systems]] use the values that are specified below.
-If you have made your own rod you will need to enter the correct measurements. See [[CalTester:CalTesterPlus:Documentation:Overview#Report_Dimensions|here]] for more information. +If you have made your own rod you will need to enter the correct measurements. See [[CalTester:CalTesterPlus:Documentation:CalTesterPlus_Doocumentation_Overview#Report_Dimensions|here]] for more information. 
-{{PlatformTutorial5.png}}+{{:PlatformTutorial5.png}}
 **6. Enter the size of your force platforms into the FP size tab.**\\ **6. Enter the size of your force platforms into the FP size tab.**\\
 (A) If not FP exists, click "Add New Force" to populate the list box\\ (A) If not FP exists, click "Add New Force" to populate the list box\\
Line 50: Line 52:
  
 If you do not enter the size of your force platform, the C3D corners are used to estimate the size. If you do not enter the size of your force platform, the C3D corners are used to estimate the size.
-{{PlatformTutorial7.png}}+{{:PlatformTutorial7.png}}
 **6. Ensure the desired C3D trials are still selected, and the settings on the main tab are correct.**\\ **6. Ensure the desired C3D trials are still selected, and the settings on the main tab are correct.**\\
 (A) **If the FP size was specified** , ensure the desired FP is selected in the drop down (FP1 in this tutorial).\\ (A) **If the FP size was specified** , ensure the desired FP is selected in the drop down (FP1 in this tutorial).\\
  
  
-{{CalTester_FPC_FinalInputPage.png}}+{{:CalTester_FPC_FinalInputPage.png}}
 **7. Click on the Go button at the bottom of the screen.**\\ **7. Click on the Go button at the bottom of the screen.**\\
  
  
-{{CalTester_Go.png}}+{{:CalTester_Go.png}}
 **8. The program will ask you where you want to save the text file that has been created with the outputs.**\\ **8. The program will ask you where you want to save the text file that has been created with the outputs.**\\
  
  
-{{PlatformTutorial8.png}}+{{:PlatformTutorial8.png}}
 **9. The text file should contain a readout similar to what was produced below from the sample files.**\\ **9. The text file should contain a readout similar to what was produced below from the sample files.**\\
  
caltester/caltesterplus/tutorials/platform.1718716965.txt.gz · Last modified: 2024/06/18 13:22 by sgranger