User Tools

Site Tools


caltester:caltesterplus:documentation:caltesterplus_doocumentation_overview

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
caltester:caltesterplus:documentation:caltesterplus_doocumentation_overview [2024/07/12 13:54] – created sgrangercaltester:caltesterplus:documentation:caltesterplus_doocumentation_overview [2024/07/17 15:44] (current) – created sgranger
Line 1: Line 1:
-====== CalTesterPlus_Doocumentation_Overview ======+====== CalTesterPlus Doocumentation Overview ======
  
 ==== Collecting CalTester Data Trials ==== ==== Collecting CalTester Data Trials ====
  
-|TOP of Rod\\ {{caltestermtd2.png}}\\ BOTTOM of Rod|- Set up your capture volume making sure that all force platforms and cameras are in the positions that they will remain in for each following data collection.\\ - Before you begin collecting - place the [[CalTester:CalTesterPlus:Hardware#Base_Plate|CalTester base plate]] on the force platform.\\ - Zero the force platform so that it will not record the force produced by the CalTester base.\\ - Begin the data capture with the [[CalTester:CalTesterPlus:Hardware#Rod_and_Markers|CalTester Rod]] not in contact with the force platform.\\ - After a second place the CalTester Rod in one of the CalTester base platform's divots, from this point on the CalTester should be the only thing that comes in contact with the force platform.\\ - Press down on the rod with a load of at least 200 N.\\ - Move the rod in either the frontal or sagittal direction:\\ - Keeping the end of the rod on the force platform stationary move the upper portion of the rod from vertical to 30 degrees from vertical, back to vertical and then 30 degrees in the opposite direction. This movement should take no less than 3 seconds and the force applied should be equal to or greater than 200 N.\\ - Each trial does not need to be more than 3 seconds long.\\ - There should be a minimum of three trials collected per force platform. Ideally there should be 5, one near each corner of the force platform and one near the center of the force platform.|+|TOP of Rod\\ {{:caltestermtd2.png}}\\ BOTTOM of Rod|- Set up your capture volume making sure that all force platforms and cameras are in the positions that they will remain in for each following data collection.\\ - Before you begin collecting - place the [[CalTester:CalTesterPlus:Hardware#Base_Plate|CalTester base plate]] on the force platform.\\ - Zero the force platform so that it will not record the force produced by the CalTester base.\\ - Begin the data capture with the [[CalTester:CalTesterPlus:Hardware#Rod_and_Markers|CalTester Rod]] not in contact with the force platform.\\ - After a second place the CalTester Rod in one of the CalTester base platform's divots, from this point on the CalTester should be the only thing that comes in contact with the force platform.\\ - Press down on the rod with a load of at least 200 N.\\ - Move the rod in either the frontal or sagittal direction:\\ - Keeping the end of the rod on the force platform stationary move the upper portion of the rod from vertical to 30 degrees from vertical, back to vertical and then 30 degrees in the opposite direction. This movement should take no less than 3 seconds and the force applied should be equal to or greater than 200 N.\\ - Each trial does not need to be more than 3 seconds long.\\ - There should be a minimum of three trials collected per force platform. Ideally there should be 5, one near each corner of the force platform and one near the center of the force platform.|
  
 ==== The CalTesterPlus Application ==== ==== The CalTesterPlus Application ====
Line 12: Line 12:
 This is the main CalTesterPlus window which opens when the application is first launched. It is divided into two sections. The top of the screen allows you to add and remove files from your CalTesterPlus workspace. The bottom half of the screen allows you to navigate between Report, Platform and Jig mode. When the program launches it defaults to the Report Mode. This is the main CalTesterPlus window which opens when the application is first launched. It is divided into two sections. The top of the screen allows you to add and remove files from your CalTesterPlus workspace. The bottom half of the screen allows you to navigate between Report, Platform and Jig mode. When the program launches it defaults to the Report Mode.
  
-{{CTFullPageReportTabOn.png}}+{{:CTFullPageReportTabOn.png}}
  
 ===== CalTesterPlus Workspace ===== ===== CalTesterPlus Workspace =====
caltester/caltesterplus/documentation/caltesterplus_doocumentation_overview.1720792477.txt.gz · Last modified: 2024/07/12 13:54 by sgranger