caltester:caltesterplus:documentation:calculations
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| caltester:caltesterplus:documentation:calculations [2024/06/26 20:12] – removed sgranger | caltester:caltesterplus:documentation:calculations [2024/09/06 13:53] (current) – [Calculations] wikisysop | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== Calculations ====== | ||
| + | |||
| + | ===== Graphics ===== | ||
| + | |||
| + | The following graphics are from the [[https:// | ||
| + | |||
| + | {{: | ||
| + | |||
| + | {{: | ||
| + | |||
| + | ===== Calculations ===== | ||
| + | |||
| + | The following calculations and explanations are from the [[https:// | ||
| + | \\ | ||
| + | **Section I : Calculating the rod orientation variable under the assumed condition of static equilibrium**\\ | ||
| + | \\ | ||
| + | |||
| + | |||
| + | Free-body diagram of testing device: Fp, ground reaction force; Fg, gravitational force (weight); Fa, applied force; r, position vector between tips (p to a) of testing device rod:\\ | ||
| + | {{: | ||
| + | Thus, r and A are parallel and the test device rod orientation (r) is defined entirely by the vector quantity A that is derived from FP measurements (Fp) and the physical characteristics of the testing device (Fg/2, i.e.the weight of the rod and its center of mass location; in this case, half the rod length).\\ | ||
| + | {{: | ||
| + | |||
| + | |||
| + | The rod orientation variable ( {{: | ||
| + | \\ | ||
| + | **Section II : Equation for evaluating the static equilibrium assumption**\\ | ||
| + | |||
| + | |||
| + | Under 2D dynamic conditions, the following holds:\\ | ||
| + | {{: | ||
| + | \\ | ||
| + | Rewriting the left-hand side of Eq. (4)\\ | ||
| + | {{: | ||
| + | \\ | ||
| + | Rearranging Eq. (5), the magnitude of the angular displacement ( {{: | ||
| + | \\ | ||
| + | {{: | ||
| + | \\ | ||
| + | where r is the length of the testing device rod, Icg the moment of inertia of the test device rod about the center of mass location, m the mass of the testing device rod and {{: | ||
| + | |||
| + | CalTesterPlus does not calculate {{: | ||
| + | |||
| + | |||