caltester:caltester_mode_overview
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
caltester:caltester_mode_overview [2024/08/01 15:35] – [Section I : Calculating the rod orientation variable under the assumed condition of static equilibrium] wikisysop | caltester:caltester_mode_overview [2025/03/31 17:22] (current) – wikisysop | ||
---|---|---|---|
Line 5: | Line 5: | ||
The functionality is **now available in Visual3D when a CalTester license key is provided**. There is also a stand-alone version of Visual3D that ONLY supports the CalTester, and these options now replace the older software. Users of the old software should have access to the new software automatically when they log into our web downloads page. | The functionality is **now available in Visual3D when a CalTester license key is provided**. There is also a stand-alone version of Visual3D that ONLY supports the CalTester, and these options now replace the older software. Users of the old software should have access to the new software automatically when they log into our web downloads page. | ||
- | **UPDATE:** The standalone CalTester-Plus software application has been discontinued and replaced with a newer CalTester | + | **UPDATE:** The standalone CalTester-Plus software application has been discontinued and replaced with a newer CalTester |
As a reminder, always go to the CalTester tab first, before opening any CalTester related data files. | As a reminder, always go to the CalTester tab first, before opening any CalTester related data files. | ||
Line 13: | Line 13: | ||
Accurate and reliable kinematics and kinetics data are essential to the appropriate application of movement analysis data for clinical and research purposes. Proper laboratory calibration includes the accurate determination of the positions of the force platform(s) and cameras in the laboratory coordinate system, as well as correct setting of [[Visual3D: | Accurate and reliable kinematics and kinetics data are essential to the appropriate application of movement analysis data for clinical and research purposes. Proper laboratory calibration includes the accurate determination of the positions of the force platform(s) and cameras in the laboratory coordinate system, as well as correct setting of [[Visual3D: | ||
- | {{: | + | {{: |
CalTester is an essential tool for laboratories that: | CalTester is an essential tool for laboratories that: | ||
Line 29: | Line 29: | ||
==== The design of the MTD2 device allows a force to be applied to the surface of the force platform without any applied moment.==== | ==== The design of the MTD2 device allows a force to be applied to the surface of the force platform without any applied moment.==== | ||
| | ||
- | The [[CalTester: | + | The [[CalTester: |
Within the CalTester mode there are two classes of functionality: | Within the CalTester mode there are two classes of functionality: |
caltester/caltester_mode_overview.1722526537.txt.gz · Last modified: 2024/08/01 15:35 by wikisysop